This device is made to DIN EN ISO 9001 standard and has left the factory in 
flawless 

condition 

regarding 

technical 

safety. 

 
To  maintain  this  condition  and  ensure  safe  operation  pay  attention  to  the 
information and warnings contained in this instruction manual. 

1.2

1.2

1.2

1.2

 

S

SS

Safety instructions

afety instructions

afety instructions

afety instructions    

 

D

D

D

DANGER

ANGER

ANGER

ANGER!!!!    

If the casing, connection cable or another part of the device is damaged, it is 
to be unplugged and switched off immediately. 

    

 

D

D

D

DANGER

ANGER

ANGER

ANGER!!!! 

Before opening the casing unplug connecting cable. 
The  screws  at  the  battery  cover  on  the  back  of  the  device  shall  not  be 

The  screws  at  the  battery  cover  on  the  back  of  the  device  shall  not  be 

The  screws  at  the  battery  cover  on  the  back  of  the  device  shall  not  be 

The  screws  at  the  battery  cover  on  the  back  of  the  device  shall  not  be 
opened.

opened.

opened.

opened.    

 

 

Warranty voids if the device is opened. 

    

 

DANGER

DANGER

DANGER

DANGER!!!!    
Ensure  that  any  repairs  to  the  unit  are  carried  out  by  qualified  personnel. 
Substantial risk for the user arises from improper repairs.    

 

Liquids  and  dust  shall  not  enter  the  device.  Don’t  expose  the  device  to 
humidity or solar radiation for any length of time!    

    

 

DANGER

DANGER

DANGER

DANGER!!!!    
Connect the CLM1000 only to approved security sockets 100-264 VAC/47-
63 Hz with protective earth conductor. 
Maximum power of any kind of load shall not exceed 4424 Watt (max. 16A). 

    

 

CAUTION

CAUTION

CAUTION

CAUTION!!!!    
If the device is diverted from its intended use or operated wrongly no liability 
can be assumed for possible harms. 

 

The device shall not be handled with abrasive and sharp-edged objects.  
The device shall not be cleaned with solvent-containing or acidic substances. 

Содержание CLM1000 Home

Страница 1: ...331 8371 99 eMail info christ elektronik de Internet http www christ elektronik de Copyright It is forbidden to reproduce or process using electronic systems copy or distribute any part of this document Translation into another language requires written authorisation This document is for the personal use of the owner of the device or Christ Elektronik GmbH personnel only Technical modifications Ch...

Страница 2: ... 2 1 2 Safety instrucions 2 2 Operation 3 2 1 CLM1000 Home operational system 3 2 2 Brief instruction 3 2 3 Contrast setting 4 3 Error handling 5 4 Technical data 6 4 1 CLM1000 variant types and measurings 6 4 2 Display and operation 7 4 3 Measuring principle and accuracy 7 4 4 Voltage supply 7 4 5 Environment and dimensions 7 ...

Страница 3: ... of the device shall not be The screws at the battery cover on the back of the device shall not be The screws at the battery cover on the back of the device shall not be The screws at the battery cover on the back of the device shall not be opened opened opened opened Warranty voids if the device is opened DANGER DANGER DANGER DANGER Ensure that any repairs to the unit are carried out by qualified...

Страница 4: ...d appliance HIFI PC and plug it in the adapter of the measuring device Subsequently connect the adapter of the measuring device to the socket Now the measuring device is interposed between load and socket so it can measure power and current consumption Menu item Menu item Menu item Menu item 1 3 1 3 1 3 1 3 When the CLM1000 is plugged in it automatically switches on and displays the instantaneous ...

Страница 5: ...saved saved saved saved even after unplugging even after unplugging even after unplugging even after unplugging the wattmeter or a mains failu the wattmeter or a mains failu the wattmeter or a mains failu the wattmeter or a mains failur r r re e e e They They They They will be will be will be will be recalled recalled recalled recalled by plugging in again by plugging in again by plugging in again...

Страница 6: ...1 CLM1000 doesn t start Unplug the CLM1000 and plug it again If the error continues to exist the CLM1000 can t be used Please send in Please send in Please send in Please send in ERROR2 ERROR2 ERROR2 ERROR2 Internal error 2 The CLM1000 shows the error and all readings are reset The CLM1000 starts a new measuring If this error keeps occurring during start up the CLM1000 has to be sent in for furthe...

Страница 7: ...parent power 0 0 4224 VA 0 1 VA 1 VA Reactive power 0 0 4224 var 0 1 var 1 var Active energy consumption 0 0000 99999 99 kWh 0 0001 0 01 kWh Active energy 24 h consumption 24 h 0 0000 108 0000 kWh 0 0001 kWh Apparent energy 0 0000 99999 99 kVAh 0 0001 0 01 kVAh Reactive energy 0 0000 99999 99 kvarh 0 0001 0 01 kvarh Consumption costs 0 00 99999 99 0 01 Consumption costs 24 h 0 00 99999 99 0 01 Tar...

Страница 8: ...easuring error Measuring error 0 3 3 digit from reading at power factor 0 3 4 4 4 4 4 4 4 4 Voltage supply Voltage supply Voltage supply Voltage supply Connection Connection Connection Connection Socket at the adapter permanent load max 16 A Supply voltage Supply voltage Supply voltage Supply voltage 100 264 VAC 47 63 Hz Power consumption Power consumption Power consumption Power consumption 4 VA ...

Отзывы: