Change Log
FEB 29 2016 –
Initial Release
SainSmart iMatic V2 Device Setup
There are a few quirks of the unit due to the poor web interface design. It is extremely reliable as long as you
follow these notes
The iMatic V2 cannot obtain an IP Address via DHCP. You will need to set the IP address of the unit
manually.
The default IP address of the unit is 192.168.1.4. To access the web interface visit
http://192.168.1.4/30000
.
If you change the ip address and/or 'port' then this will change to
http://ipaddress/port
.
If you access the Change IP/Port page make sure you complete the port change as this stops control of
the unit. Take note that the port is not an actual port number but a folder name.
Driver Installation
1.
The driver you have downloaded will be in a zip file. Double click on this file to open it in your preferred zip
program (WinZip, WinRar, etc.).
2.
Extract the c4i file to the My Documents\Control4\Drivers directory. If you are using Windows 7 or 8 this will be
extracted to the Libraries\Documents\Control4\Drivers directory.
3.
You are now ready to add and configure the driver via the Composer Pro software.