Chore-Tronics® 3 Breeder Edition Control
Control Setup
11
Chore-Time Load Cells
1.Install the load cell system per the Load Cell installation manual.
2.Connect the CT 3 IO terminals to the SJB IO net terminals.
Calibration
1.Go to the Setup/Analog Inputs/Load Cell Screen and Select Calibrate.
2.With no feed in the Bin select the OK Button. If there is no error then continue.
3.At the Chore-Tronic's 3 in the Weight Calibration Scale screen enter the known weight in the Bin and the units
wanted from the dropdown. Example shows 500 lb.
3