9
PTM007
ATTACHING CIRCULAR CONNECTOR TO 4
-
STRAND CABLE
Circular connectors come with 4 pins numbered from 1 to 4. Using PigTek
’
s standard 4
-
strand
cable, ST99422, the connector
’
s should be installed as follows:
PIN 1
→
BLACK
PIN 2
→
PIN 3
→
RED
PIN 4
→
GREEN
If connecting to the Chore
-
Time PigCentral control, only one end of the cable should be fitted
with a circular connector. The other end should be stranded and stripped on each end as it
will be attached to the control. If being attached to the standalone control, both ends must be
fitted with circular connectors.
CHORE
-
TIME CONTROL CONNECTION
The following instructions apply for use on
the PigCentral® control ONLY:
After running the cable from the bin slide
motor to the location of the control, con-
nect the cable to a bin side card inside the
control. The bin slide can be connected to
either channel A or B.
A 24 volt supply will also need to be con-
nected to the bin slide card. PigTek offers
this item as PT4015.
WIRING
Included with the Automatic Bin Slide is an female M8 circular connector, ST78004, or two
with a twin slide. These circular connectors must be attached to a shielded and UV
-
resistant 4
strand cable, such as PigTek
’
s ST99422. Instructions for wiring are described below:
Figure 6: Control card wiring diagram
Motor A +
Motor A
-
Motor B +
Motor B
-
24 Volt Supply
-
24 Volt