Feeder Line Assembly and Suspension
LIBERTY® Feeding System with Electronic Sensor (ES)
22
11.Install the Metal Water Tight Connector in the Feed Line Motor (single phase applications only).
Cut the Flexible Conduit to length. Slide the wires from the end control through the Flexible
Conduit. Install the Flexible Conduit in the connectors. Connect the wires to the Feed Line Motor.
12.Attach all covers and wires according to the wiring section of this manual.
13.Pull the auger at the boot end until it begins stretching. Then let it relax. In the relaxed position,
mark the auger at the end of the boot.
14.Auger stretch:
The auger needs to be stretched 7"
[180 mm]
per 100’
[30 m]
. Example: A 300’
[90 m]
feeder line
requires 21"
[500 mm]
of stretch.
Beginning at the
relaxed
position, measure the required amount of stretch. Mark the auger at that
point.
Grip the auger 8"
[200 mm]
ahead of this mark with locking pliers. Allow the auger to pull back
into the boot so that the pliers rest against the end of the boot.
90 deg. Metal connector in motor
Wire Form
Insulator
Clamp with Anti-Roost
racket and Insulator
Plastic Conduit Connector
Spring should be stretched
3/4" to 1" [19mm to 25mm]
Clamp
Flex Conduit
Ground Wire
Motor Wire Connections
Figure 37.Connecting Conduit
1523-103 4/2002
Mark the
relaxed
auger
at the end of the boot
Figure 38.Wiring the Motor