![Chore-Time KONAVI Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/chore-time/konavi/konavi_installation-and-operators-manual_2603216043.webp)
Maintenance
43
Mechanical Switch Adjustment
procedure for Control Units
Refer to
A. Turn the adjustment nut counter-clockwise
until the switch clicks.
B. Turn the adjustment nut clockwise until the
switch clicks.
C. Turn the adjustment nut counter-clockwise
3/4 turn.
Proximity Sensor Adjustment
Sensitivity Timer
: The Feeder Comes with the Sensitivity Timer adjustment Screw factory set and Glued in
position. (Do not Adjust).
Time Delay
: The Delay Time is Factory Set to 3 Minutes.
See
To adjust the Time Delay:
•For less time — turn Time Delay Selector counter-clockwise.
•For more time — turn Time Delay Selector clockwise.
Figure 49.Switch Adjustment
Adjustment
Nut
Figure 50.Proximity Sensor Adjustment
Item
Description
1
Delay Time Adjustment Screw
2
Sensitivity Adjustment Screw
3
Proximity Sensor
2
1
The Sensitivity Adjustment
Screw is set at the factory and
glued in place.
The Delay Adjustment Screw is set
to the "7 o’clock" position at the fac-
tory. At the "7 o’clock" position the
Delay time is 3 minutes.
1
2
3
4
5
6
7
End Control
Mid-line Control
3