Chore-Time FLEX-IR ST73000 Скачать руководство пользователя страница 7

The FLEX-IR™ should be attached directly to the power unit funnel as shown on page 6. Below 
the FLEX-IR™ a 3” PVC tube can be used to extend to the feeder. If a 3” tube is used, make 
sure the tube is fully inserted into the FLEX-IR™ to provide a smooth inner wall for feed to 
slide on. 

In some applications a 4” tube may be required below the FLEX-IR™ in order for feed to 
completely clear out of the FLEX-IR™ sensor. In this case the 3” tube would not be used and a 
4” tube would go around the outside of the outlet of the FLEX-IR™. In any case the extension 
tube below the FLEX-IR™ should be straight and not get smaller as it approaches the feeder or 
else feed bridging will result. 

If the tubing from the power unit funnel to the feeder is required to be at an angle, such as 45 
degrees, a 45 degree elbow should be placed between the FLEX-IR™ and the power unit funnel. 
An elbow should not be placed between the FLEX-IR™ and the feeder unless it causes the feed 
flow to be more vertical. 

A "Y" drop at the last feeder may require the addition of an extra drop in the line right before 
feed reaches the power unit. This extra drop would supply one side of the "Y" and the FLEX- 
IR™ mounted at an angle on the power unit funnel would supply the other side of the "Y". 

Electrical Wiring 

The FLEX-IR™ is capable of operating a feed motor up to 1.5 HP at 240 volts without an 
external relay. Use of an external relay above these loads is required; use of an external relay at 
or below these loads is optional. 

Description of FLEX-IR™ Wires: 

Black:  50-300 VAC 
Blue: 

50-300 VAC 

Red: 

Dry Contact 

Orange: Dry Contact 

Grounding is not required. 

Содержание FLEX-IR ST73000

Страница 1: ...FLEX IR Feed System Control Installation and Operating Instructions Item Number ST73000 May 2018 MA FLEXIRGBA1...

Страница 2: ...tance of User Installer Manual 4 2 FLEX IR Overview 5 3 Description of Timer Features 5 4 Operating Instructions 5 5 Installation 6 6 FLEX IR WiringDiagrams 8 7 Alarm Connections 9 8 Accessing Setup M...

Страница 3: ...accident or lack of proper maintenance shall not be considered defects under thiswarranty 5 This warranty applies only to systems for the care of pork and livestock Other applications in industry or c...

Страница 4: ...cial or consequential damages resulting from the use of the information contained in this User Installer Manual The instructions contained in this User Installer Manual are not intended to cover all d...

Страница 5: ...r Delay start is the time in minutes from when feed falls away from the sensor until the auger starts This delay prevents short cycling of the system Maximum run time Maximum run time is the amount of...

Страница 6: ...IR Feed System Control involves both electrical and tubing applications Installing the tubing Connect the FLEX IR to other feed system components with metal screws or pins In general applications the...

Страница 7: ...unit funnel to the feeder is required to be at an angle such as 45 degrees a 45 degree elbow should be placed between the FLEX IR and the power unit funnel An elbow should not be placed between the FL...

Страница 8: ...8 6 FLEX IR WIRING DIAGRAMS...

Страница 9: ...ems Multiple FLEX IR s may be connected together using the examples below To connect the FLEX IR to the alarm system remove 3 screws and remove the top of the FLEX IR enclosure Use a small screwdriver...

Страница 10: ...EFAULT 1 BLIP RED ZONE RUN SIGNAL 2 BLIPS 30 DELAY START AFTER POWERUP CONFIGURE 0 0 SECOND DELAY START 1 BLIP 30 3 SECOND DELAY START DEFAULT 2 BLIPS 60 6 SECOND DELAY START 3 BLIPS 90 9 SECOND DELAY...

Страница 11: ...ring Feeders empty and FLEX IR not turning system on System timed out feed bridged below FLEX IR internal or external relay bad Feed goes past FLEX IR and system does not stop Internal or external rel...

Страница 12: ...x 800 236 6118 E mail sales pigtek net Internet www pigtekamericas com Printed in the U S A Contact your nearby Chore Time distributor or representative for additional parts and information Distributo...

Отзывы: