Installation
57" Endura
®
Fan
24
MV2406P
Motor Wiring
1. Check that the electrical power
being supplied to the Fan
matches the electrical Specifica-
tions on the Fan and Motor
Decals.
2. Remove the Motor Access
Cover.
3. Install an electrical disconnect
within reach of each Fan
installed.
4. Connect the cord to the motor
according to the wiring diagram
on the motor. Verify that the
motor is connected for counter
clockwise rotation (viewing the
back of the motor, opposite the
shaft end.)
5. Follow local, state, and national
electrical codes for wiring.
6. Attach the Cord to the Wall using
a Screwhook
as shown
. Allow
enough slack in the cord to form
a "drip loop" for moisture to fall
away from the cord and not into
the motor.
Screwhook
Motor Access Cover
Drip Loop