57" Endura
®
Fan
Installation & Operator’s
Instruction Manual
Fan Part Numbers and Specifications
Operating static pressure should be less than 0.15 inches water column [37.5 Pa].
The Fan Inlet and exhaust must be kept clear of obstructions. Failure to keep the Fan
airflow path clear of obstructions could cause loss of Fan performance and Fan damage.
MV2406P
August 2018
Static Pressure at
.10" w.c.
[25 Pa]
Static Pressure
at .15" w.c.
[37.5 Pa]
Fan Part No.
Bess Lab
Test No.
Voltage
Phase
Hz
Nominal
RPM
Amps Starting
Amps
CFM
[cmh]
CFM/W
[cmh/W]
CFM
[cmh]
CFM/W
[cmh/W]
53464-21
53464-21S
12615
230
1
60
542
6.9
36.0
30400
[51600]
20.4
[34.7]
28400
[48200]
18.1
[30.7]
53464-22
53464-22S
12614
230
1
60
543
5.4
27.5
27100
[46100]
23
[39.1]
25100
[42700]
20.1
[34.2]
53464-23
17224
230
1
60
538
4.0
27.5
21200
[36000]
24.6
[41.7]
18900
[32200]
20.8
[35.3]
53464-41
53464-41S
12616
230
3
60
534
4.8
40.0
30000
[51100]
20.9
[35.6]
27800
[47200]
18.1
[30.8]
53464-42
53464-42S
12619
230
3
60
539
4.1
40.0
26900
[45600]
23.3
[39.6]
24800
[42200]
20.4
[34.6]
53464-51
53464-51S
12617
230
3
50
527
5.2
45.0
29500
[50100]
20.8
[35.3]
27200
[46200]
18.1
[30.8]
53464-52
53464-52S
12618
230
3
50
534
4.7
45.0
26500
[45100]
22.9
[38.9]
24500
[41600]
20.1
[34.1]