57" Assembled & Unassembled Direct Drive Endura® Fan
Endura® DD Fan New Installation Planning
7
Planning the layout of the spacing between Fans is very important. Spacing too close together will cause
interference between the discharge Cones. See the Invertek ODE-3 IP66 Outdoor User Guide, (MV2493) at
www.choretime.com/documents, Manuals, Ventilation, Fans & Shutters, 57-Inch Endura Fans, MV2493
for additional drive mounting requirements.
Endura
®
DD Fan New Installation Planning
!Important:
Provide Shelter over Cones in areas where
snow or ice could cause damage. CTB Inc. Warranty
Does
Not
cover damage from external sources.
57-3/8" [145.7cm] Max.
55-1/4" [140.3cm] Min.
Important!
Fan
mounting
surface must be flat.
5" [12.7cm]
60-1/16" [152.5cm]
Minimum Spacing if
sides of Cone are
flattened
72" [182.9cm]
Recommended Spacing
70
-1/8" [178.1cm]
60
-1/8" [152.7cm]
4-5/16"
[10.9cm]
7-1/2" [19.1cm] Shroud Mounting
Surface to Motor/Screen.
Minimum Wall Thickness 6" [15.2cm]
42-13/16"
[108.7cm]
5-11/16"
[14.4cm]
57-1/16
" [
14
4.
9c
m] Ma
x.
55-5/8"
[
141.
3c
m]
Mi
n.
60-1/4"
[
1
53cm]
1-3/4" [4.4cm] required at
the bottom of the opening.
60-1/4" [153.0cm]
10
" [25.4cm]
6-3/8"
[16.2cm]
6" [15.2cm]