Installation
10
Model 108 Single and Twin Intermediate Fill Cap Kit
1.Place the Sponge Tubing
(Item 12)
over the lip of the bin fill collar.
2.Install the short Tube Anchor Weldment
(Item 8)
on the outside of the Bin Cover Weldment
(Item 11).
3.Caulk or silicone the Anchor Tube Weldments against the Cover Weldment.
4.Install the Slide Shut-offs on the Tube Anchor Weldments.
5.Install the Tube Anchor Weldment
(Item 5)
on the inside of the Cover Weldment
(Item 11)
.
6.Set the Cover Weldment over the bin opening in line with the supply bin.
7.Install the Auger Tubes from the boot on the supply bin to the Cover Weldment.
8.Use a Tube Clamp
(Item 9)
to secure the Auger Tube(s) to the Tube Anchor Weldment(s).
9.Drill holes and fasten the Cover Weldment
(Item 11)
to the bin fill collar with the 5/16" x 1-1/2" bolts and
locknuts supplied.
(40526) Twin Fill Kit
(40527) Single Fill Kit
40526
40527
Item Description
Part No.
1
Danger Electrical Decal
2527-25
2527-25
2
Danger Moving Auger Decal
2527-9
2527-9
3
Lid Assembly
7689
7689
4
Shut-off Half
40530
40530
5
Twin Tube Fill Weldment
40522
--
Single Tube Fill Weldment
--
40523
6
Over Center Clamp
2536
2536
7
Double Insulated Bushing
6343
6343
8
Tube Anchor Weldment
4-37332
4-37332
40526
40527
Item Description
Part No.
9
Tube Clamp
14373
14373
10
Tube Insert
34337
34337
11
Twin Cover Weldment
40533
--
Single Cover Weldment
--
40534
12
Sponge Tubing
5928
5928
--
Cord
3085-8
3085-8
--
Red Indicator Ball
24393-1
24393-1
--
Green Indicator Ball
24393-2
24393-2
Figure 6.Single and Twin Intermediate Fill Cap Assembly