4
Matters need attention
Overload of electrical motor (The electrical motor would be overload in
the following condition)
The voltage of the electric is on the low side;
The protection certification of the electric motor is set inappropriate;
The motor overloads at very low speed during long time;
How to solve above problems:
Reset the V/F curved shaped and the torque data;
Check the power source;
Adjust the working load or choose another inverter which is suitable for the
capacity of electric motor;
When low speed of motor and long working time is needed, choose the
exclusive frequency conversation electric motor.
Overload of inverter :( The inverter motor would be overload in the
following condition)
Overload;
Accelerating time is too short;
When the electric motor is initiated, after a short stop;
V/F curved is set improperly or the torque data is too much;
How to solve above problems:
Change the inverter whose capacity is matching;
Prolong the accelerate time;
Renew the V/F cured shape or the torque data.