Chiko CKU-400AT-HC-V1 Скачать руководство пользователя страница 5

1.4 

運転

 

Operation 

 

運転中に移動させないで下

Do not move it during the operation.

 

停電した時には、電源を切

Turn OFF the power when
Otherwise, injury or product damage may be caused when the product recover

 

フィルタを取り外したり、目詰
ブロア内への異物が混入して

Operation  without  filter  or  with  a  clogged  and  damaged  filter  may  cause  trouble,  because  foreign 
substances enter the blower. Install the filter properly before operating the machine.

1.5 

修理・分解・改造

   

Repair, disassembly and modification

 

本体を分解・改造しないで
連絡して下さい。

 

Do not disassemble or modify the 
Disassembly and modification may cause 
Contact your dealer for internal inspection a
 

1.6 

廃棄

 

 

Disposal

 

 

産業廃棄物として適切に処分

Dispose of the product properly as industrial waste

 

2

 

製品到着時の確認

 

 

開梱されましたら、各部の
万一、運送途中での破損

After unpacking, make sure that all parts

Contact our company immediately if parts are damaged during transportation or not provided.

 

本体

 

Main Body

 

製品ネームプレートは本体に貼

Confirm the nameplate.

 

 

フィルタ(本体にセットされています

Filter

set in the machine

  1

次フィルタ

Primary filter

  2

次フィルタ

Secondary filter

 

排気フィルタ

Exhaust filter

 

 

電源ケーブル(付属)とリモートケーブル
Power cable(standard accessory)

 

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

電源ケーブル

Power cable

※  ケーブルは地域によって
※  The cable is different in each 

リモートケーブル(別売)   

Remote cable(option)

(3m)

抜け防止の設計となっております
下さい。

(ピンの位置を必ず

The remote cable is so designed as to be prevented from falling off.
Insert it securely with its dent facing downward.
(Make sure to confirm pin positions.)

Copyright  CHIKO  AIRTEC  CO.,

 

  4

 

 

下さい。

 

Do not move it during the operation. 

切って下さい。復旧時に、けが・装置破損の原因になります。

Turn OFF the power when an instantaneous power interruption occurs. 
Otherwise, injury or product damage may be caused when the product recover

目詰まりや破損した状態で運転すると、

 

して、故障の原因となります。  正しくフィルタを取り付けてご使用

peration  without  filter  or  with  a  clogged  and  damaged  filter  may  cause  trouble,  because  foreign 

substances enter the blower. Install the filter properly before operating the machine.

Repair, disassembly and modification

 

しないで下さい。感電・けがの原因になります。内部の点検や修理はお

Do not disassemble or modify the machine. 
Disassembly and modification may cause an electrical shock and injury. 
Contact your dealer for internal inspection and repair. 

処分してください。

 

Dispose of the product properly as industrial waste. 

  Confirmation and Preparation at Arrival

の不足部品がないかご確認下さい。

 

破損・部品不足などがございましたら、すぐにご連絡下

After unpacking, make sure that all parts are provided. 

Contact our company immediately if parts are damaged during transportation or not provided.

貼っていますので、ご確認下さい

 

されています)

 

machine

 

・・・・

 

・・・・・

 

FB-40

 

 

Secondary filter

・・・・・・・

 

CHF-3535-70 

Exhaust filter

・・・・・・・・・

 

CHF-HEP-3535-69 

とリモートケーブル(別売)

 

 

(standard accessory) and Remote cable(option) 

ower cable

 

(3m)  ×1 

によって異なります。 

The cable is different in each region.

 

    MT-173-8 

m)  ×1 

となっております。くぼみを下にし、しっかりと差し込んで

ず確認してください) 

The remote cable is so designed as to be prevented from falling off. 
Insert it securely with its dent facing downward. 
(Make sure to confirm pin positions.) 

100-110V 

200V 

チコーエアーテック株式会社 

Copyright  CHIKO  AIRTEC  CO.,  LTD.  2009

 

 

 
 

 

Otherwise, injury or product damage may be caused when the product recovers. 

使用ください。

 

peration  without  filter  or  with  a  clogged  and  damaged  filter  may  cause  trouble,  because  foreign 

substances enter the blower. Install the filter properly before operating the machine. 

はお買い上げになった販売店に

reparation at Arrival 

連絡下さい。

 

Contact our company immediately if parts are damaged during transportation or not provided.

 

200V 

国内

Japan

 

200V 

海外

Other than Japan

 

Содержание CKU-400AT-HC-V1

Страница 1: ...ng saving type clean box that realizes air technology in a compact body ual thoroughly and handle this CKU Series machine correctly so that you can use safely for a long time and enjoy its full perfor...

Страница 2: ...losive dust the following substances Flammable substances Gasoline thinner benzene kerosene Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high c...

Страница 3: ...ctor 8 4 4 Confirmation before operation SK 250AT 450AT 8 4 5 Operation procedure 9 5 Remote Cable Sold Separately 10 5 1 Electrical circuit diagram 10 5 2 Remote Cable 10 5 3 Color and signal of each...

Страница 4: ...room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical parts to fail and may cause an electrical shock 100 Provide sufficient spa...

Страница 5: ...when the product recover peration without filter or with a clogged and damaged filter may cause trouble because foreign substances enter the blower Install the filter properly before operating the mac...

Страница 6: ...ag Exhaust filter Copyright CHIKO AIRTEC CO 5 Name and Structure of Product Name of main body Standard accessories Collecting Adsorbing fine dust and fumes Protecting the circuit and the electrical pa...

Страница 7: ...upply The power supply is single phase supply voltage range is 10 The power cable of 3 m with a grounding plug is included AT panel Operating the product with a different power supply may cause burst...

Страница 8: ...eases by 1 level Minimum suction level Approximately 60 Hi 1 1 100 Hi switch Every time this switch is pressed the performance increases by 1 level Maximum suction level 100 ON switch and OFF switch t...

Страница 9: ...grounding plug are connected correctly insulation is provided properly and the rated voltage is realized Confirm items 1 to 3 above and then proceed to the item 4 AT Turn ON the MAIN POWER switch and...

Страница 10: ...ration procedure Connect the power plug to the electrical outlet suction hose hood to a proper position Turn ON the MAIN POWER switch and confirm that the power indicator Press the ON switch to start...

Страница 11: ...n the ON and the panel is impossible to Temperature correction is not provided 3 5 6 F Attach a noise limiter Approximately 33 F to the output terminals Nos 1 2 and 3 When adding 33 0 1 1 2 3 5 6 8 7...

Страница 12: ...The AT panel is disabled while the wires 4 and 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Impedan...

Страница 13: ...in body Transfer required output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when y...

Страница 14: ...the primary filter ter bag replace the secondary filter Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting Using a...

Страница 15: ...he filter case The filter paper packing of the primary filter is inserted into the cylindrical pipe of the filter case Lightly push down the filter paper packing to remove it snap locks on the left an...

Страница 16: ...tion Frequency Description Before operation Is the case closed completely Once day Is the exhaust port unclogged Once day Are no abnormal vibrations generated Is the installation level correct Once mo...

Страница 17: ...hat the motor is not overheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error sta...

Страница 18: ...450 100V Single phase 8 2 50 60 7 2 85 73 40 1 dB Note The Noise column indicates a value dB on the scale A at 1 m on the main body side when the hose is connected to the suction port 10 Consumable P...

Страница 19: ...ect to change without prior notice Memo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 1 1 33 1 1 33 Hakush...

Отзывы: