Chapter 5
Maintenance
and Checkup
54
5.5
Errors/Warnings
If an error/warning occurs, the self-diagnosis function built-in the device lights (flashes) the ERROR
lamp and shows display data and error number alternately on the display.
For a description of errors/warnings displayed, see
“5.5.2 Error/Warning Table” (page 55)
.
For faults and conditions not covered by self-diagnosis, see
“5.6 Troubleshooting” (page 56)
.
5.5.1
Action on Errors/Warnings
If the self-diagnosis function of this device has detected an error or warning, take the steps below to
clear the error or warning.
The screenshots for illustration are provided as examples.
1.
If an error/warning occurs, the ERROR lamp
lights (flashes) and the display shows display
data and error number alternately.
If there are two or more error/warning
occurrences, the one with the highest priority
is displayed.
(Display data)
Displayed alternately
(Error No.)
2.
Press the MODE SELECT button to move to
the error history mode.
If there are two or more error/warning
occurrences, the number of occurrences
precedes the error number.
3.
If there are two or more error/warning
occurrences, press the Up/Down arrow
buttons to check the error numbers.
↑ / ↓
4.
Take an action appropriate for the error
number shown on the display.
“5.5.2 Error/Warning Table” (page 55)
5.
Press the MODE SELECT button to move to
the error clear mode.
6.
To clear the error/warning, press the ENTER button to return to normal mode.
To leave the error/warning uncleared, press the MODE SELECT button to return to normal mode.
If an error/warning is left uncleared:
- For an error/warning that continues the operation ... All buttons remain enabled.
- For an error/warning that stops the operation ............ The ON button is disabled.
To resume the operation, clear the error/warning.
IMPORTANT
• Once WARN6 or WARN7 is cleared, it will not reappear until the main power switch
is turned off and back on.
ERR04
?????
2:ERR04
Error number with highest priority
Number of error/warning
occurrences
1:WARN4
2:ERR04
ERROR CLEAR
Y
Содержание CBA-080AT3-HI-UL1
Страница 27: ...第 6 章 便利な使い方 オプション CMN604 003 25 日 本 語 第6章 便利な使い方 オプション 6 1 リモートケーブル 6 1 1 標準接続図 ...
Страница 32: ...第 7 章 付録 30 7 3 電気回路図 7 3 1 CBA 080AT3 HI UL1 UL2 7 3 2 CBA 500AT3 HI UL1 UL2 これらの基板は説明 のため反体面を透視 した状態で記載して ...
Страница 33: ...第 7 章 付録 CMN604 003 31 日 本 語 7 3 3 CBA 1200AT3 HI V1 UL2 ...
Страница 65: ...Chapter 7 Appendix CMN604 003 Original instructions 63 English 7 3 3 CBA 1200AT3 HI V1 UL2 ...
Страница 67: ...MEMO ...