![Chigo CCA-18HVR1 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/chigo/cca-18hvr1/cca-18hvr1_technical-manual_2601243095.webp)
R410A50Hz Universal Outdoor Series Technical Manual
92
GUANGDONG CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
10 The Specification of Power
Model
18kBtu/h
24kBtu/h
36kBtu/h
Indoor power supply
V/Ph/Hz
220~240/1/50
Outdoor power supply
V/Ph/Hz
220~240/1/50
Connection
wiring
Outdoor Power Supply
From indoor unit
From indoor unit
Power supply
individually for
indoor and
outdoor
Power wiring
mm
2
3×2.5
3×2.5
3×1.5 / 3×4.0
Signal wiring
mm
2
4×2.5
4×2.5
3×1.0
Model
36kBtu/h
48kBtu/h
60kBtu/h
Indoor power supply
V/Ph/Hz
220~240/1/50
Outdoor power supply
V/Ph/Hz
380-415/3/50
Connection
wiring
Outdoor Power Supply
Power supply individually for indoor and outdoor
Power wiring
mm
2
3×1.5 / 5x2.5
Signal wiring
mm
2
3×1.0