CMS-260
Installation Instructions
4
ASSEMBLING COLUMN
1.
Cut off 1-1/2" NPT pipe at desired length.
2.
Drill a 5/16" hole 1" from end of pipe. (See Figure 1)
Figure 1
3.
Slide CMS-260 (A) onto end of pipe and attach with a
5/16 x 1/2" button head cap screw (B) or 5/16 x 1/2" button
head security cap screw (C). (See Figure 2)
Figure 2
4.
Attach and tighten two 5/16 x 1/4" set screws (D) or two
5/16 x 1/4" security set screws (E) into side of CMS-260 (A).
(See Figure 3)
Figure 3
Install the 1-1/2" NPT threaded column with the attached
CMS-260 following instructions provided with the column.
5/16" x 1
1" from end of pipe
2
Pipe
3
(B) or (C) x 1
(A)
4
(D) or (E) x 2