7 Shut-down warning
7.1 Description
A shut-down warning will appear in the event of:
•
Too high a temperature at the outlet of the compressor element.
•
Too high a dewpoint temperature (Full-Feature compressors).
7.2 Compressor element outlet temperature
If the outlet temperature of the compressor element exceeds the shut-down warning level (see section
), warning LED (5) starts blinking.
1.
Press the Scroll down button.
The screen shows the temperature at the compressor element outlet.
The screen shows that the temperature at the element outlet is 122 °C
It remains possible to scroll through other screens, using the Scroll buttons up and down (12) to check the actual status
of other parameters.
2.
Press button (11) to stop the compressor and wait until the compressor has stopped.
3.
Switch off the voltage, inspect the compressor and remedy.
The warning message will disappear as soon if the warning condition disappears.