Topping up of coolant
–
Verify if the engine cooling system is in a good
condition (no leaks, clean,...).
–
Check the condition of the coolant.
–
If the condition of the coolant is outside the limits,
the complete coolant should be replaced (see
section “Replacing the coolant”).
–
Always top-up with GENCOOL EG.
–
Topping up the coolant with water only, changes
the concentration of additives and is therefore not
allowed.
Replacing the coolant
Drain
–
Completely drain the entire cooling system.
–
Used coolant must be disposed or recycled in
accordance with laws and local regulations.
Flush
–
Flush twice with clean water. Used coolant must
be disposed or recycled in accordance with laws
and local regulations.
–
From the Chicago Pneumatic Instruction book,
determine the amount of GENCOOL EG required
and pour into the radiator top tank.
–
It should be clearly understood that the risk for
contamination is reduced in case of proper
cleaning.
–
In case a certain content of ‘other’ coolant remains
in the system, the coolant with the lowest
properties influences the quality of the ‘mixed’
coolant.
Fill
–
To assure proper operation and the release of
trapped air, run the engine until normal engine
operation temperature is reached. Turn off the
engine and allow to cool.
–
Recheck coolant level and add if necessary.
Storage of the generator
Storage
–
Store the generator in a dry, frost-free room which
is well ventilated.
–
Run the engine regularly, e.g. once a week, until it
is warmed up. If this is impossible, extra
precautions must be taken:
•
Consult the engine’s operator manual.
•
Remove the battery. Store it in a dry, frost-free
room. Keep the battery clean and its terminals
lightly covered with petroleum jelly. Recharge
the battery regularly.
•
Clean the generator and protect all electrical
components against moisture.
•
Place silica gel bags, VCI paper (Volatile
Corrosion Inhibitor) or another drying agent
inside the generator and close the doors.
•
Stick sheets of VCI paper with adhesive tape
on the bodywork to close off all openings.
•
Wrap the generator, except the bottom, with a
plastic bag.
In case of a mix of different coolant
products this type of measurement
might provide incorrect values.
Содержание CPG 90-120 JD
Страница 1: ...CPG 90 120 JD Instruction Manual for AC Generators English ...
Страница 2: ......
Страница 19: ... 19 This is the described menu flow for changing the unit type ...
Страница 47: ... 47 Circuit diagrams ...
Страница 48: ... 48 1310 3200 01 00 Applicable for CPG 90 120 John Deere Power circuit ...
Страница 49: ... 49 ...
Страница 51: ... 51 ...
Страница 52: ... 52 1310 3200 00 00 Applicable for CPG 90 120 John Deere Engine circuit Qc1002TM ...
Страница 53: ... 53 ...
Страница 55: ... 55 ...
Страница 56: ...Printed in Belgium 04 2010 1310 3012 23 www cp com ...