bank is likely connected in se-
ries (a negative terminal of one
battery attached to a positive
terminal of another) instead of in
parallel. Carefully examine the
diagram and correct the wiring
before attaching to the inverter.
Turn the Power Switch on the front
8.
of the inverter off.
Connect the output cables from the
9.
battery bank to the inverter.
OpERATION
FRONT
pOWER SWITcH
ON
OFF
OVER
lOAd
TEmp
OVER
VOlTAgE
AmpS
OuT 1
OuT 2
FIguRE d
1.
Plug the 120 V~ device(s) you wish to power into the 3-prong AC Receptacles.
The tools/appliances must not use more than 2,000 (total) Watts during continu-
ous operation, otherwise it may overload the Inverter.
(See Figure d.)
Turn the Power Switch to the
2.
“ON”
position.
(See Figure d.)
Turn on the tool/appliance. If an alarm sound is heard, turn off the tool/appliance.
3.
Unplug the tool/appliance from the Inverter and discontinue using the tool/appli-
ance with the Inverter.
NOTE:
4.
Some rechargeable tools/appliances may damage the Inverter or the
tool/appliance. When first using a rechargeable device, check the Inverter’s
temperature for the first ten minutes. If it becomes abnormally hot, do not use the
device with the Inverter.