SKU 93096
Page 5
For technical questions, please call 1-800-444-3353.
BACK
Connection
For the power Inverter to work properly, your power source must provide 12 volts DC,
and enough current (i.e., 32 amps to operate a load of 384 Watts or under).
Warning: This Inverter must only be connected to batteries with a nominal out-
put voltage of 12 volts. More voltage could damage the Inverter or the device
being powered. If more than one 12 volt battery is to be used, the batteries must
be connected in a parallel circuit; batteries connected in a series circuit will
produce too much voltage.
1.
Place the Power Inverter on a flat surface. Make sure it has adequate ventila-
tion and is not in direct sunlight. Fasten the Inverter securely to the surface,
using screws or some other means. If holes are to be drilled, follow safe, proper
installation techniques.
2.
Strip the insulation off of the last
3
/
4
” of each Battery Cable (not included; #4-#0
AWG cable recommended). Insert the Cables into the (Positive) red and (Nega-
tive) black terminals on the back of the Inverter. Securely tighten the Screw on
top of each connection. Connect the Ground Cable (not included; #6 AWG or
larger cable recommended) lug to the Ground Terminal, see
BACK
above. Se-
curely tighten.
3.
The Power Inverter can be used either while the engine is running or off. Con-
nect the Battery Cables to the (Negative) black and (Positive) red terminals of
the battery.
4.
Connect the Ground Cable to the appropriate location below:
a.
If this unit is mounted within a vehicle with a grounded metal chassis,
attach the Ground Cable to a nearby location on the chassis.
b.
If this unit is mounted in a boat or vehicle with an ungrounded chassis,
attach the Ground Cable to the vehicle’s grounding system.
c.
ONLY if this unit is being used outside a vehicle,
attach the Ground Cable to the Negative Cable leading into the Inverter.
Negative
Positive
Charger
AC Input
Ground
Terminal
Charger
Fuse Holder
WARNING!
Risk of Fire!
The positive battery terminal connection must
be the LAST connection and must be done with the inverter’s switch off.
REV 06/06