SETUP

Grounding

TO PREVENT ELEcTRIc SHOcK AND DEATH FROM INcORREcT GROUNDING 

WIRE cONNEcTION: 

check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded.  

Do not modify the power cord plug provided with the tool.  Never remove the grounding prong from 

the plug.  Do not use the tool if the power cord or plug is damaged.  If damaged, have it repaired by a service 

facility before use.  If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools: Tools with Three Prong Plugs

3-Prong Plug and Outlet

1.  Tools marked with “Grounding Required” have a three 

wire cord and three prong grounding plug.  The plug 

must be connected to a properly grounded outlet.  

If the tool should electrically malfunction or break 

down, grounding provides a low resistance path to 

carry electricity away from the user, reducing the risk 

of electric shock.  

(See 3-Prong Plug and Outlet.)

2.  The grounding prong in the plug is connected through 

the green wire inside the cord to the grounding 

system in the tool.  The green wire in the cord must 

be the only wire connected to the tool’s grounding 

system and must never be attached to an electrically 

“live” terminal.  

(See 3-Prong Plug and Outlet.)

3.  The tool must be plugged into an appropriate outlet, 

properly installed and grounded in accordance with 

all codes and ordinances.  The plug and outlet should 

look like those in the preceding illustration.   

(See 3-Prong Plug and Outlet.)

Double Insulated Tools: Tools with Two Prong Plugs

Outlets for 2-Prong Plug

1.  Tools marked “Double Insulated” do not 

require grounding.  They have a special 

double insulation system which satisfies 

OSHA requirements and complies with 

the applicable standards of Underwriters 

Laboratories, Inc., the Canadian Standard 

Association, and the National Electrical Code.

2.  Double insulated tools may be used in either of the 

120 volt outlets shown in the preceding illustration.

   

(See Outlets for 2-Prong Plug.)

Extension cords

1. 

Grounded

 tools require a three wire extension cord.  

Double Insulated

 tools can use either 

a two or three wire extension cord.

2.  As the distance from the supply outlet increases, 

you must use a heavier gauge extension cord.  

Using extension cords with inadequately sized wire 

causes a serious drop in voltage, resulting in loss of 

power and possible tool damage.  

(See Table A.)

3.  The smaller the gauge number of the wire, the 

greater the capacity of the cord.  For example, 

a 14 gauge cord can carry a higher current 

than a 16 gauge cord.  

(See Table A.)

4.  When using more than one extension cord to make 

up the total length, make sure each cord contains at 

least the minimum wire size required.  

(See Table A.)

Содержание 69820

Страница 1: ......

Страница 2: ...ation which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMPORTANT SAFETY INFORMATION General Power Tool Safety Warnings Read all safety w...

Страница 3: ...igger or energizing power tools that have the Trigger on invites accidents 4 Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected s...

Страница 4: ...emakers should consult their physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure In addition people with pacemak...

Страница 5: ...on to the hand past hand injuries nervous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any symptoms related to vibration such as tingling numbness and white or b...

Страница 6: ...ctrically live terminal See 3 Prong Plug and Outlet 3 The tool must be plugged into an appropriate outlet properly installed and grounded in accordance with all codes and ordinances The plug and outle...

Страница 7: ...Table A RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 240 VOLT NAMEPLATE AMPERES at full load EXTENSION CORD LENGTH 25 50 75 100 150 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18...

Страница 8: ...e 8 For technical questions please call 1 800 444 3353 Item 69820 Safety Operation Maintenance Setup Specifications Electrical Rating 120V 60Hz 10A No Load Speed 900 1600 FPM Belt Size 4 W x 24 L 2548...

Страница 9: ...f this manual including all text under subheadings therein before set up or use of this product Note For additional information regarding the parts listed in the following pages refer to Parts List an...

Страница 10: ...he power cord must reach the work area with enough extra length to allow free movement while working 3 Secure loose workpieces using a vise or clamps not included to prevent movement while working 4 T...

Страница 11: ...ake sure the arrows on the inside of the new sanding belt are pointing in the direction of rotation as indicated on the housing of the tool d Push the Belt Tension Release Lever back in to secure the...

Страница 12: ...te 2 Eliminate use of extension cord If an extension cord is needed use one with the proper diameter for its length and load See Extension Cords in Grounding section on page 6 Performance decreases ov...

Страница 13: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Страница 14: ...Sleeve 1 20 Left Housing 1 21 Front Bushing Frame 1 22 Dust Bag 1 23 Small Belt Pulley 1 24 Drive Belt Cover 1 25 Nameplate 1 26 Screw M4x14 4 27 Spring Washer 4 2 28 Washer 4 2 29 Brush Holder 2 30 C...

Страница 15: ...Page 15 For technical questions please call 1 800 444 3353 Item 69820 Safety Operation Maintenance Setup Assembly Diagram...

Страница 16: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Отзывы: