Page 9

For technical questions, please call 1-888-866-5797.

Item 68988

Sa

FE

ty

Op

ER

at

IO

n

Ma

Int

Enanc

E

SE

tup

Extension cords

1. 

Grounded

 tools require a 

three wire extension cord.  

Double Insulated

 tools can use either 

a two or three wire extension cord.

2.  As the distance from the supply outlet 

increases, you must use a heavier gauge 

extension cord.  Using extension cords with 

inadequately sized wire causes a serious 

drop in voltage, resulting in loss of power 

and possible tool damage.  

(See table a.)

3.  The smaller the gauge number of the wire, 

the greater the capacity of the cord.  For 

example, a 14 gauge cord can carry a higher 

current than a 16 gauge cord.  

(See table a.)

4.  When using more than one extension cord 

to make up the total length, make sure 

each cord contains at least the minimum 

wire size required.  

(See table a.)

5.  If you are using one extension cord for more 

than one tool, add the nameplate

 

amperes 

and use the sum to determine the required 

minimum cord size.  

(See table a.)

6.  If you are using an extension cord 

outdoors, make sure it is marked with the 

suffix “W-A” (“W” in Canada) to indicate 

it is acceptable for outdoor use.

7.  Make sure the extension cord is properly 

wired and in good electrical condition.   

Always replace a damaged extension 

cord or have it repaired by a qualified 

electrician before using it.

8.  Protect the extension cords from 

sharp objects, excessive heat, 

and damp or wet areas.

table a:  Recommended Minimum 

Wire Gauge for Extension cords* 

(120/240 Volt)

naMEplatE

aMpERES

(at full load)

EXtEnSIOn cORD 

lEnGth

25´

50´

75´

100´

150´

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

* Based on limiting the line voltage drop to 

five volts at 150% of the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V

Volts

~

Alternating Current

a

Amperes

n0 xxxx/min.

No Load Revolutions 

per Minute (RPM)

WARNING marking concerning  

Risk of Eye Injury.  

Wear ANSI-approved safety 

goggles with side shields.

Read the manual before 

set-up and/or use.

WARNING marking concerning  

Risk of Fire.  

Do not cover ventilation ducts.

Keep flammable objects away.
WARNING marking concerning 

Risk of Electric Shock.  

Properly connect power 

cord to appropriate outlet.

Содержание 68988

Страница 1: ...dry place for future reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2011 by Ha...

Страница 2: ...tion which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury Important Safety Information General Power Tool Safety Warnings Read all safety wa...

Страница 3: ...ohol or medication A moment of inattention while operating power tools may result in serious personal injury 2 Use personal protective equipment Always wear eye protection Protective equipment such as...

Страница 4: ...ons taking into account the working conditions and the work to be performed Use of the power tool for operations different from those intended could result in a hazardous situation Service Have your p...

Страница 5: ...the material If saw blade is binding it may walk up or kickback from the workpiece as the saw is restarted d Support large panels to minimize the risk of blade pinching and kickback Large panels tend...

Страница 6: ...ring operation 25 Do not leave the tool unattended when it is plugged into an electrical outlet Turn off the tool and unplug it from its electrical outlet before leaving 26 Use clamps not included or...

Страница 7: ...ury 1 Anyone using vibrating tools regularly or for an extended period should first be examined by a doctor and then have regular medical check ups to ensure medical problems are not being caused or w...

Страница 8: ...vides a low resistance path to carry electricity away from the user reducing the risk of electric shock 2 The grounding prong in the plug is connected through the green wire inside the cord to the gro...

Страница 9: ...ked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always replace a damaged extension co...

Страница 10: ...fore Use Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product Note For additional info...

Страница 11: ...speed steel abrasive blades or metal or masonry cutting blades The guards of this saw are not designed to protect against the failure of such blades Mounting and Removing Blade 1 Hold in the Spindle...

Страница 12: ...Depth Scale Figure D Adjusting Bevel 1 Loosen the Bevel Lock Lever to allow the angle of cut to be adjusted 2 Use the Bevel Scale to set the desired angle 3 After adjustment tighten the Bevel Lock Lev...

Страница 13: ...depth b Place Saw on flat level surface c Remove Oil Plug and check oil level Level should not be below bottom threads d Add 5 to 10 weight Worm Drive Lubricant until it runs out of the Oil Plug hole...

Страница 14: ...ce and Lubrication 1 BEFORE EACH USE inspect the general condition of the tool Check for loose hardware misalignment or binding of moving parts cracked or broken parts damaged electrical wiring and an...

Страница 15: ...Performance decreases over time 1 Accessory dull or damaged 2 Carbon brushes worn or damaged 1 Keep cutting accessories sharp Replace as needed 2 Have qualified technician replace brushes Excessive no...

Страница 16: ...nty of any kind to the buyer that he or she is qualified to make any repairs to the product or that he or she is qualified to replace any parts of the product In fact the manufacturer and or distribut...

Страница 17: ...fety Operation Maintenance Setup Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustratio...

Страница 18: ...Worm 1 36 Locking Pin 1 37 Special Nut 1 38 Check Ring 1 39 Spring 1 40 Washer 1 41 O Ring 1 42 Special Nut 1 43 O Ring 1 44 Screw 5 45 Gearbox Cap 1 46 Auxiliary Handle 1 Part Description Qty 47 Scre...

Страница 19: ...Page 19 For technical questions please call 1 888 866 5797 Item 68988 Safety Operation Maintenance Setup Assembly Diagram...

Страница 20: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or impl...

Отзывы: