taBle a – minimum Wire gauge
For eXtenSion cordS
(120 Volt)
ampere
rating
(at full load)
eXtenSion cord
lengtH
25’
50’
100’
150’
0 – 6
18
16
16
14
6 – 10
18
16
14
12
10 – 12
16
16
14
12
12 – 16
14
12
Not recommended
Table A shows the correct size to use
depending on cord length and name-
plate ampere rating. If in doubt, use
the next heavier guage. The smaller
the gage number, the heavier the
cord. To reduce the risk of disconnec-
tion of appliance cord from the exten-
sion cord during operating:
a. Make a knot as shown in Method of
Securing Extension Cord; or
Use one of the plug-receptacle
b.
retaining straps or connectors de-
scribed in this manual.
Ground Fault Circuit Interrupter
3.
(GFCI) protection should be provided
on the circuit(s) or outlet(s) to be
used for the Air Dryer. Receptacles
are available having built-in GFCI
protection and may be used for this
measure of safety.
note: this air dryer has a 3-prong,
grounded power plug.
Do not Abuse Cord - Do not carry this
4.
Air Dryer by it’s cord or yank the cord
to disconnect from receptacle. Keep
the cord from heat, oil, and sharp
edges.
Use only three-wire outdoor exten-
5.
sion cords that have three-prong
grounding plugs and grounding re-
ceptacles that accept the Air Dryer’s
plug.
This Air Dryer should be grounded
6.
while in use to reduce the risk of
electric shock to the operator. The
appliance is equipped with a 3-con-
ductor cord and 3-prong grounding
plug to fit the proper grounding recep
-
tacle. The green or green and yellow
conductor in the cord is the grounding
wire. Do not connect the green or
green and yellow wire to a live termi-
nal.
Your Air Dryer has a plug as illustrat-
ed above. The outlet used should
look like the outlet illustrated above.
do not remove the grounding