background image

SKU 65309 

For technical questions, please call 1-800-444-3353. 

Page 10

OPeRaTinG inSTRucTiOnS

  Read the enTiRe iMPORTanT 

SaFeTY inFORMaTiOn 

section at the beginning of this 

manual including all text under 

subheadings therein before set 

up or use of this product.

  inspect Generator and 

equipment looking for 

damaged, loose, and missing 

parts before set up and starting.  

if any problems are found, do 

not use equipment until fixed 

properly.

Start Procedure

  before starting the engine:

Follow the Set up instruc-

a. 

tions to prepare the equip-

ment.  Follow all instructions 

in the separate tractor man-

ual.

inspect the generator and 

b. 

tractor.

Fill the tractor engine with 

c. 

the proper amount and type 

of fuel and oil.

Set the tractor on a flat surface.  Set 

1. 

the brake on the tractor.  Ensure that 

it is not in gear, and cannot move dur-

ing operation.
Unplug all loads from the Generator 

2. 

before starting to prevent permanent 

damage to connected devices.
Start and operate the tractor accord-

3. 

ing to the provided engine manual.
Engage the tractor PTO drive.

4. 

Set the tractor’s PTO speed to 540 

5. 

RPM.

Test each GFCI outlet by pressing the 

6. 

TEST button.  The green light on that 

outlet should go out.  Then press the 

RESET button.  The green light on 

that outlet should come back on.  If 

either GFCI outlet does not function 

as described have a qualified electri

-

cian repair the generator before use.
With the devices turned OFF, plug the 

7. 

devices into the appropriate outlets.

cauTiOn!

 Do not plug in or unplug 

electrical loads while the loads are 

turned on.
Turn on the devices one at a time 

8. 

from the largest to the smallest. 

Check the frequency meter reading 

on the Control Panel.  If the reading 

has dropped below 60 Hz, do not 

connect any additional loads.
Be sure that all devices are in good 

9. 

working order before connecting 

them to the generator. If a device 

begins to operate abnormally, be-

comes sluggish, or stops suddenly, 

turn off the device. Then disconnect 

the device and examine it for signs of 

malfunction.

note:

 If an overloaded circuit causes the 

AC circuit breaker to switch off, re-

duce the electrical load on the circuit 

and wait a few minutes before reset-

ting the circuit breaker.
The DC terminal may be used operat-

10. 

ing 12 VDC portable devices only.

WaRninG:

 Do not use this generator 

to charge 12 VDC  batteries without a 

charge controller. Directly charging a 

12 Volt battery may cause the battery 

to overheat and possibly explode. 

Содержание 65309

Страница 1: ...re using this product Failure to do so can result in serious injury Save this manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual p...

Страница 2: ...hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury WARNING Read all instructions Failure to follow all instructions listed below may result in fire serious injury and or DEATH The warnings and precautio...

Страница 3: ...nsed electrician with a UL approved cut off switch that will automatically disconnect the home from the power grid when the generator is being used Check with the local utility company before having a generator hard wired to a building Make sure the generator is properly 8 grounded to avoid electrical shocks Connect a 6 ga or larger insulated copper wire to the Ground Con nection on the Control Pa...

Страница 4: ...cemakers should 7 consult their physician s before use Electromagnetic fields in close proximity to a heart pacemaker could cause pacemaker interference or pacemaker failure Caution is neces sary when near the engine s magneto or recoil starter Use only accessories that are recom 8 mended by Harbor Freight Tools for your model Accessories that may be suitable for one piece of equipment may become ...

Страница 5: ... one exten 3 sion cord to make up the total length make sure each cord contains at least the minimum wire size required See Table A If you are using one extension cord 4 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 5 outdoors make sure it is marked with the suffix W A W in Canada to indic...

Страница 6: ...e 2 key after use Unconditioned electrical power can 3 damage sensitive equipment Use a line conditioner sold separately be tween this generator and the devices Maintain labels and nameplates on 4 the equipment These carry impor tant information If unreadable or missing contact Harbor Freight Tools for a replacement Store equipment out of the reach of 5 children Save these instructions ...

Страница 7: ...nd 5 circuit breakers Use a 4 blade grounded connector to operate 125 250 V 60 Hz single phase loads requiring up to 50 Amps of current up to 12 000 Watts 12kW of power Use a connector rated to 250 Volts 50 Amps with a same rated 4 wire set The 50 Amp circuit break ers protect each hot line of the circuit Single 12V DC receptacle 6 Used to power 12VDC loads at 8 3 Amps Volt Frequency Time Digital ...

Страница 8: ...haft b PTO guard c Set Up Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product To prevent serious injury from accidental starting Turn the Power Switch of the equipment to its OFF position wait for the engine to cool and disable the engine before assembling or making any a...

Страница 9: ...gle of the Drive shaft U joints Note Aligning the shafts minimizes tor sional forces which tend to topple the Generator Minimizing vertical angles reduces friction heat and wear on the U joints of the PTO shaft Attach the generator to the tractor us 5 ing all 3 connection points and appro priate hardware not included The connection method must prevent the generator from twisting during opera tion ...

Страница 10: ...essing the 6 TEST button The green light on that outlet should go out Then press the RESET button The green light on that outlet should come back on If either GFCI outlet does not function as described have a qualified electri cian repair the generator before use With the devices turned OFF plug the 7 devices into the appropriate outlets CAUTION Do not plug in or unplug electrical loads while the ...

Страница 11: ...10 V or the voltage requirement of attached devices remove some devices from the system to reduce demand on the generator WARNING To prevent serious injury from electric shock Use the GFCI unit properly If the power supply to either duplex outlet is interrupted there may be a short in the attached device s wiring that is tripping the GFCI unit Check all wiring connections carefully for moisture an...

Страница 12: ...engine and equipment Perform regular visual inspection of 1 the Generator and PTO shaft Look for loose or broken wires or defective connections Check for missing cor roded or loose fasteners Be sure all shields and guards are in good condi tion Inspect for general condition and cleanliness Keep the generator clean and free of 2 dirt grease or debris Clean it regu larly and whenever it becomes dirt...

Страница 13: ...gen erator Immediately after shutting down 3 while the oil is still warm remove the Oil Drain Plug 21 along with the Oil Fill Plug 31 to help the oil to drain Catch the draining oil in a suitable 4 container Dispose of the used oil properly After all the used oil has drained 5 replace and tighten the Oil Drain Plug 21 Slowly add SAE 90W Oil until the 6 oil is visible at least halfway up the Gearbo...

Страница 14: ... clean dry cloth 2 Check and top off Gearbox oil level 3 Lubricate PTO shaft as explained 4 previously Apply a thin coat of rust preventive oil 5 to all uncoated metal parts Cover and store in a dry well ventilat 6 ed area out of reach of children For cold weather operation store the 7 equipment in a cool dry area to prevent condensation and premature wear ...

Страница 15: ...place rotor 5 Sparking at brushes Generator is overloaded 1 Brushes not seated properly 2 Brushes sticking in holder 3 Brushes worn to less than 3 8 4 Reduce load 1 Contour and re seat brushes 2 Remove brushes clean holder and 3 reinstall brushes Replace brushes NOTE Replace 4 brushes in pairs Follow all safety precautions whenever diagnosing or servicing the equipment or generator PLEASE READ THE...

Страница 16: ...put Shaft 1 27 Sealed Bearing 6306 2Z 1 28 Gasket 1 29 Gearbox Cover Plate 1 30 Oil Level Plug 1 31 Gearbox Oil Fill Plug 1 PARTS LIST Part Description Q ty 32 Control Panel Frame 1 33 Control Panel Window 1 34 Control Panel Gasket 1 35 GFCI Receptacle 2 36 Meter 1 37 Locking 125V Socket 1 38 250 V Socket 1 39 Circuit Breaker 50A 2 40 Circuit Breaker 30A 1 41 T Receptacle 1 42 Circuit Breaker 20A ...

Страница 17: ...SKU 65309 For technical questions please call 1 800 444 3353 Page 17 ASSEMBLY DIAGRAM ...

Страница 18: ...SKU 65309 For technical questions please call 1 800 444 3353 Page 18 Wiring Diagram ...

Страница 19: ...llow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date...

Отзывы: