Chicago Electric 45416 Assembly and Скачать руководство пользователя страница 5

SKU 45416

Page 5

REV 04/02

MOUNTING PLATE

FOR

GENERATOR / ALTERNATOR 10KW

SKU 45416

A mounting plate (not included), similar to the one illustrated below, will need to be provided by the
customer to properly and safely mount and operate the generator/alternator.  The plate is needed to
properly tension the drive belt used to drive generator/alternator.  Drawing below  is for reference only
and customer may need to make further modification to mounting plate and their generator frame for
the proper and safe mounting of the generator/alternator.  The drawing gives dimensions for the plate
and generator/alternator footprint.

THE MANUFACTURE AND OR DISTRIBUTOR HAS PROVIDED THE MOUNTING PLATE DIAGRAM AS A
REFERENCE TOOL ONLY.  THE CUSTOMER CAN CHOOSE TO DESIGN, MANUFACTURE AND USE THEIR
OWN MOUNTING PLATE.  THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER
MANUFACTURING OF A MOUNTING PLATE THAT IS NOT INSTALLED PROPERLY AND SAFELY
MANUFACTURED.

DRAWING NOT TO SCALE, FOR REFERENCE ONLY !!

Note: Performance of this tool may vary depending on variations of the power driver motor.

Warning: The warnings, cautions, and instructions discussed in this instruction manual
cannot cover all possible conditions and situations that may occur. It must be under-
stood by the operator that common sense and caution are factors which cannot be
built into this product, but must be supplied by the operator.

Material: 1/2” steel plate

Содержание 45416 Assembly and

Страница 1: ...93011 Visit ourWeb site at http www harborfreight com Copyright 2001 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 45416 REV 09 03 ...

Страница 2: ...o not force tool It will do the job better and more safely at the rate for which it was intended Do not use inappropriate attachments in an attempt to exceed the tool capacity 6 Use the right tool for the job Do not attempt to force a small tool or attachment to do the work of a larger industrial tool There are certain applications for which this tool was designed Do not modify this tool and do no...

Страница 3: ...15 Guard against electric shock Prevent body contact with grounded surfaces such as pipes radiators ranges and refrigerator enclosures 16 Replacement parts and accessories When servicing use only identical replacement parts Use of any other parts will void the warranty Only use accessories intended for use with this tool Approved accessories are available from Harbor Freight Tools 17 Do not operat...

Страница 4: ...minal speed of 3600 RPM Increases in speed could damage rotating parts of the Generator Slower speeds could damage the Generator or appliances connected to the Generator due to low voltage 6 Always follow national and local safety codes 7 Do not start the Generator with appliances connected and turned on 8 If the driver motor is a gas engine do not used in an enclosed area due to the carbon monoxi...

Страница 5: ...footprint THE MANUFACTURE AND OR DISTRIBUTOR HAS PROVIDED THE MOUNTING PLATE DIAGRAM AS A REFERENCE TOOL ONLY THE CUSTOMER CAN CHOOSE TO DESIGN MANUFACTURE AND USE THEIR OWN MOUNTING PLATE THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER MANUFACTURING OF A MOUNTING PLATE THAT IS NOT INSTALLED PROPERLY AND SAFELY MANUFACTURED DRAWING NOT TO SCALE FOR REFERENCE ONLY Note Performanc...

Страница 6: ...p holes on mounting plate and generator alternator 5 Insert one 1 5 16 18 hex head bolt in each through hole in mounting plate and generator alternator Insure that heads of bolts are below the surface of the mounting plate 6 Place one 1 flat washer lock washer and hex nut on each bolt and tighten 7 Turn and place generator alternator back on mounting plate 8 Replace both fan covers part 26 and wir...

Страница 7: ...ed on the pulleys to determine the proper distance between drive shafts Allow room for adjustments after mounting the Generator 4 For safe operation install a pulley guard not included around both pulleys Operation 1 Plug in the extension cords or appliances making sure they are turned off Refer to the connector wiring illustration on the next page Do not overload the Generator Calculate the total...

Страница 8: ...enerator with compressed air Do not blow directly into the heat vents Do not immerse in water Use a damp cloth do wipe clean Never insert rags tools or any device into the Generator openings 2 Periodically operate the Generator 3 Store in a clean and dry location 4 Check and tighten belts when they become loose 5 Check and tighten pulley set screws SKU 45416 Page 8 REV 02 02 04 02 09 03 120 Volt D...

Страница 9: ... ORIGINAL PRODUCT OR REPLACEMENT PARTSTHERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO SKU 45416 Page 9 REV 02 02 04 02 04 03 09 03 1 Over Current Protector 20 amp 2 1A Over Current Protector 30 amp 2 2 Spring washer GB93 87 M4 4 3 AC Socket 120V 120V 1 4 AC Socket 120V 240V 1 5 Bolt GB818 85 M5x12 13 6 Spring Washer GB93 87 M5 13 7 Washer GB 97 1 85 5 13 8 Over Curre...

Страница 10: ...NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts SKU 45416 Page 10 REV 04 02 04 03 09 03 Note Voltmeters 29 located on Wiring Box are not shown ...

Страница 11: ...SKU 45416 Page 11 REV 09 05 Schematic Diagram ...

Отзывы: