Troubleshooting
King Edge
6-20
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
The force required to move the upper spreader clamps along the linear rods is normally 2-5 pounds. If
there is extra tension on the belt, the movement may be erratic or slow. If the belt is too lose it may skip on
the pulley.
Flatwork Not Properly Spread
Message Reads:
UPPER SPREADER STALLED
1. Excessive tension in the
upper spreader belt.
Refer to the
REPAIR
chapter,
Spreader Section
section,
Upper
Spreader Belt Tension Adjustment
procedure.
•
2. Excessive friction in the
rail-carriage assembly.
Lubricate the rail. Refer to the
PRE-
VENTIVE MAINTENANCE
chapter,
Weekly PM
section,
Lubricate Up-
per Spreader Rail
procedure.
•
3. Upper spreader encoder
(PX9) malfunction.
Check. Adjust/replace as neces-
sary. Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor
Positioning Adjustment
procedure.
•
4. Home sensor (PX12) mal-
function.
Check. Adjust/replace as neces-
sary. Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor
Positioning Adjustment
procedure.
•
5. Taut sensors (PE14 L/R)
malfunction.
Check. Adjust/replace as necessary.
Refer to the
REPAIR
chapter,
Sen-
sors
section,
Taut Photosensor
Alignment
procedure.
•
6. The inverter may need to
be adjusted.
Adjust the inverter. Contact the fac-
tory Service Department.
•
7. Defective run relay (CR4)
or fuse.
Test and/or replace.
•
8. Spreader timing out of
adjustment.
Refer to the
CHI PANEL OPERA-
TION
bulletin, spreader related
Adjustment
and
Testing
sections.
•
Upper Spreader Clamps Bang
or Drag at the Center of the Unit
(continued on next page)
1. Upper spreader encoder
(PX9) out of adjustment/
malfunctioning.
Check. Adjust/replace as neces-
sary. Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor
Positioning Adjustment
procedure.
•
2. Home sensor (PX12) out of
adjustment/malfunctioning.
Check. Adjust/replace as neces-
sary. Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor
Positioning Adjustment
procedure.
•
6.7 Spread Section
Содержание King Edge
Страница 1: ...KING EDGETM Large Piece Spreader Feeder INSTRUCTION MANUAL...
Страница 66: ......
Страница 122: ......
Страница 182: ......
Страница 183: ...King Edge 3024 016c C 1 King Edge Spreader Feeder CHI PANEL OPERATION KING EDGE TYPE 00 04 PROGRAMS...
Страница 200: ......
Страница 202: ......
Страница 207: ...5 King Edge PL 3038 008M This Page Blank on Purpose...
Страница 218: ...16 PL 3038 008M King Edge Drive Detail Left 23 18 5 17 20 1 3 19 2 25 24 22 21 4 15 7 6 16 16 8 9 10 14 13 12 11...
Страница 240: ...38 PL 3038 008M King Edge This Page Left Blank On Purpose...
Страница 260: ...2...
Страница 262: ...4...
Страница 264: ...6...
Страница 266: ...8 C...
Страница 268: ...10...
Страница 270: ...12...
Страница 272: ...14...
Страница 274: ...16...
Страница 276: ...18...
Страница 277: ...19...
Страница 278: ...20...
Страница 280: ...22...
Страница 281: ...23...
Страница 282: ...24...
Страница 284: ...Skyline S1 S20 Installation...
Страница 285: ......
Страница 286: ...Skyline S1 S20 Installation...
Страница 288: ......
Страница 290: ......