Chiayo SQ-5016 Скачать руководство пользователя страница 2

 

SQ-5016

 

UHF Handheld Microphone

 

Parts and functions 

 

1. 

Cartridge 

2. 

Battery weak/power LED 

3. 

Power switch 

4. 

LCD 

5. 

Battery compartment 

6. 

Bottom cap 

7. 

Locking button 

8. 

Setting button 

9. 

Up button 

10. 

Charging port 

11. 

Down button 

 

Battery installation & indicator 

○ 

 

 

● 

 

When the microphone is switched ON, the 
power indicator 

 will blink once to denote 

the batteries are in good condition. 

If the LED remains illuminated, it means the 
batteries are weak and require replacement. 

   

   

 

This microphone requires two AA batteries to 
operate. 

To install, remove the battery cover and slide 
the batteries into the battery compartment & 
replace the battery cover. 

Note

:  Batteries  contain  corrosive  acid  that  may  leak  and  damage  the  microphone  when  stored  for  a  long 

period. Batteries should be removed from the microphone before storing without use for more than 4 weeks. 

 
 

Channel setting 

Use 

UP

 / DOWN

 button to go to the 

CHANNEL

FREQUENCY page. 

     

 

Press and hold the 

SET

 button for 2 

seconds, then the upper-right channel 
number will flash to allow changes to be 
made. 

     

 

Press 

UP

 / DOWN

 buttons to change 

the channel number. The corresponding 
frequency will change accordingly. 

     

 

After selecting a channel, press and hold 
the 

SET

 button for 2 seconds or wait 9 

seconds to save the setting. 

 

 

 

2

3

4

5

6

9

10

11

7

8

1

SET

LOCK

SET

LOCK

SET

LOCK

SET

LOCK

Отзывы: