background image

 

GMC-60

 

Gooseneck Microphone Audio Convertor

 

Parts and functions 

 

 

 

 

 

 

 

 

 

 

 

 

Note

: Port 

 indicators do not function with 

GM-143

 RJ-45 unlockable versions ( 

 ). To 

operate the locking port ( 

 ) connection, please refer to P.6. 

 

 

Advisory 

1. DO NOT TURN ON

 the power of the 

GMC-60

 convertor before all network cables are all 

connected and installation is completed. 

2. 

The network cable Cat.5e / Cat.6 UTP has to meet TIA/EIA-568-B.2 standards with copper 
wires of 24AWG-1/0.49A*4P (CM/UL).  

3. 

To achieve best performance and stable function

ality, it’s recommended to use standard 

CHIAYO CAT.5e network cables which are available in 2M, 5M and 10M length.  
Do not use cables of unknown origin because they will cause unexpected system 
abnormalities. 

4. 

The chairman unit 

GM-243C

 can be located anywhere in the loop. 

5. 

This conference system may consist of up to 120 units with max two 

GM-243C 

chairman units. 

6. 

To prevent feedback noise, please adjust the GAIN knob to control the sensitivity of the 
microphone, and set a proper output volume on the amplifier or mixer before operating the 
system. 

7. 

I

f it’s necessary to DIY cables, be sure to examine them with RJ-45 cable tester until they are 

no problem before installation. 

 

 

P O W E R

P W R

P O R T 1

P O R T 2

P O R T 3

P O R T 4

P O R T 5

P O R T 6

S Y S T E M

C

S

G ooseneck M icrophone C onverter

GMC-60

P O R T 1

P O R T 2

P O R T 3

P O R T 4

P O R T 5

P O R T 6

L IN K

D C I N

L I N E O U T

B A L A N C E D

15V 4.3A

Power ON/OFF 

Power indicator 

Input port indicator 

Chairman-Delegate system switch 

Series connection port 

Input port 

DC input (15V 4.3A) 

Unbalanced audio 

output (Φ6.3mm)

 

Balanced audio 

output (XLR) 

Содержание GMC-60

Страница 1: ...HIAYO ELECTRONICS CO LTD Operation manual GMC 60 Gooseneck Microphone Audio Convertor P O W E R P W R P O R T1 PO R T2 P O R T3 PO R T4 P O R T5 PO R T6 SY STE M C S Gooseneck Microphone Converter GMC 60 ...

Страница 2: ... system abnormalities 4 The chairman unit GM 243C can be located anywhere in the loop 5 This conference system may consist of up to 120 units with max two GM 243C chairman units 6 To prevent feedback noise please adjust the GAIN knob to control the sensitivity of the microphone and set a proper output volume on the amplifier or mixer before operating the system 7 If it s necessary to DIY cables be...

Страница 3: ...a its rear port to support more GM 243 units IMPORTANT Each system expansion max includes two GMC 60 convertors and 120 GM 243 units For more unit installation please set up another system with GMC 60 to cover the rest GM 243 units and output the audio to the amplifier mixer 2 Only the GM 243C s chairman priority function is integrated as the same system power supply and audio connection must be s...

Страница 4: ...H of both convertors to C position slide to C P O W E R P W R P O R T1 P O R T2 P O R T3 P O R T4 P O R T5 P O R T6 S Y S TE M C S GooseneckMicrophone Converter GMC 60 S S S S S S S S S S S S S S S S C C SYSTEM C S P O W E R P W R P O R T1 P O R T2 P O R T3 P O R T4 P O R T5 P O R T6 S Y S TE M C S GooseneckMicrophoneConverter GMC 60 S S S S S S S S S S S S S S S S S S SYSTEM C S C S P O W ER PW R...

Страница 5: ... S P O W E R P W R PO R T1 PO R T2 P O R T3 P O R T4 P O R T5 PO R T6 S Y S TE M C S GooseneckMicrophone Converter GMC 60 S S S S S S S S S S S S S S S S S S P O W E R P W R PO R T1 PO R T2 PO R T3 P O R T4 P O R T5 PO R T6 S Y S TE M C S GooseneckMicrophoneConverter GMC 60 S S S S S S S S S S S S S S S S S S C C SYSTEM C S SYSTEM C S LINK ...

Страница 6: ...vertor and the other end to the MIC IN jack of the mixer amplifier Single GMC 60 convertor Single GMC 60 convertor Linked GMC 60 convertors Linked GMC 60 convertors PORT1 PORT2 PORT3 PORT4 PORT5 PORT6 LINK DC IN LINE OUT BALANCED 15V 4 3A PORT1 PORT2 PORT3 PORT4 PORT5 PORT6 LINK DC IN LINE OUT BALANCED 15V 4 3A PORT1 PORT2 PORT3 PORT4 PORT5 PORT6 LINK DC IN LINE OUT BALANCED 15V 4 3A PORT1 PORT2 P...

Страница 7: ...6 Instructions Insert the plug Pull out the plug 1 2 3 4 5 6 7 8 9 Lock bar Use finger to push the lock bar to the bottom Done 1 2 3 4 5 6 7 8 Lock bar Prepare to unlock Push lock bar Locked ...

Страница 8: ...p www chiayo com tw Email sales chiayo com tw Office 30 Lane 27 Section 4 Jen Ai Road Taipei 10685 Taiwan Tel 886 2 27415741 Fax 886 2 27525242 Factory 88 Chung Hsiao Street 2 Chiayi 60080 Taiwan Tel 886 5 2711000 Fax 886 5 5767611 ...

Отзывы: