Chexx Automations K-2000A Скачать руководство пользователя страница 5

 

NOTE: If the keyboard in partition 5, display also selects 5, it means display can receive all 

signals 0001-9999 from keyboard. 

 

F8 Key Settings   
E1 Single-key or Multi-key Setting 

1---Single key 

2---Multi key 

E2 Voice pairing 

1. Press “

” key 2 seconds, screen displays F1   

2. Press “

” key seven times, screen displays F8, press “

” screen displays E1 

3. Press “

” to display E2 and Press “

” to confirm, and you will see 00 (sound cancel)   

4. Press “

””

” to select the number (voice) you want.   

For example,  if  you  want  “emergency”,  you  select  26 ,  And  press “emergency “ key from 

button. Then you will hear success. 

5. Press “

” again to exit setting state 

When you press Emergency button, you will hear “XX number Emergency”   

 

F9 Restore factory setting 

1. Press “

” key 2 seconds, screen displays F1   

2. Press “

” key 8 times, screen displays F9, press “

” screen displays E1 

3. Keep press “

” 2 seconds to confirm, you will hear a voice (success),   

 

F0 Date &Time Setting 

Enter  F0,  you  will  see  the  Minute  Area  is  flashing,  use 

”  to  adjust  the 

minute. 

Press the “

” key, to navigate.. After setting the time and date, Press “

” again to exit 

setting state 

 