![CHERUBINI A520016 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/cherubini/a520016/a520016_instructions-manual_2596533009.webp)
MAINTENANCE
The Rugiada sensor needs no particular maintenance. However any dust or residue that
collects on its surface will limit its sensitivity. Therefore, it is suggested that it be cleaned
off once or twice a year with a damp cloth. Make sure to have disconnected the power
source prior to cleaning, otherwise contact with the sensor could engage the opening
and closing of the awning by triggering an alarm, possibly causing harm to the person
involved or others.
18
DELETING THE RUGIADA SENSOR
To delete the sensor from the motor, an already programmed remote control must be
used. The deleting sequence is the following:
2 sec
SET
TESTS AND OPERATION
Once the the Rugiada sensor has been activated the sensor element is ready to detect any
alarm conditions. Pressing the SET button, the unit will operate in “test” mode for the next
3 minutes, or in case of alarm, the awning will close or open and, once it has completed
that action, it will be possible to immediately trigger another alarm. It is even possible to
activate the sensor by simply placing your hand on top of the sensor element.
WHAT TO DO IF....
Symptom
Cause
Remedy
Failure to open or
close the awning in
case of rain.
Sensor has no power.
Check the power cable for the
sensor.
Presence of residue on the
sensor element.
Clean the surface the sensor
element with a damp cloth after
disconnecting the power.
*Note:
the Rugiada sensor is compatible only with the indicated
motors and control units, manufactured beginning 01/2014.