3
Supplier’s Federal Identification Code: 11815
TM-G704B_SR; Rev.: A
Date: 11/06/13
DCR# 13-1687
SAFETY WARNINGS
Do not use beyond the design intent; do not use substitute components for repair.
Operating this tool with a damaged or missing stem deflector, or using the deflector as a handle, may result
in severe personal injury. Rotate the pin deflector facing away from the operator
Wear proper PPE when operating, repairing or overhauling this tool
(
.)
Any modification will void warranty and shall be at the customer's entire responsibility.
Maintain the tool in a safe working condition at all times and examined at regular intervals for damage.
Before disassembling the tool for repair, refer to the maintenance instructions. All repairs shall be undertaken
only by personnel trained in Cherry installation tools.
Disconnect the air line from the tool inlet before servicing, adjusting, fitting or removing any accessory.
Ensure that the vent holes do not become blocked or clogged and the hoses are in good condition.
Wash thoroughly after handling the fluid; excessive contact could cause rashes.
Operating air pressure not to exceed 110 psi (7.6 bar); use of a pre-set regulator (P1505) is recommended
Do not operate the tool without the pulling head in place.
All retaining rings, screwed end caps, air fittings, trigger valves and pulling heads should be attached securely
and examined at the end of each working shift.
Do not pull rivet in the air or directed at any person.
Do not pound on the rear of the tool head to force rivets into holes as this will damage the tool.
Safety warnings must be explained all operators as part of training.
FLUID SAFETY AND FIRST AID INFORMATION (ATF
type “A”)
SKIN EXPOSURE:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate
attention. If irritation develops, consult a physician.
INGESTION:
Seek medical attention immediately. DO NOT INDUCE VOMITING.
INHALATION:
No significant adverse health effects are expected to occur on short term exposure. Remove from
contaminated area. Apply artificial respiration if needed. If unconscious, consult physician.
Eyes:
Flush with copious amounts of water. If irritation develops, consult a physician.
FIRE:
Suitable extinguishing media: CO2, dry powder, foam or water fog. DO NOT use water jets.
ENVIRONMENT
Waste Disposal: In accordance with local, state and federal regulations.
SPILLAGE
Prevent entry into drains, sewers and water courses. Soak up with diatomaceous earth or other inert material.
Store the spent fluid in appropriate containers for disposal.
HANDLING:
Eye protection required. Protective gloves recommended. Chemically resistant boots and apron
recommended. Use in well-ventilated area
COMBUSTIBILITY
: It is slightly combustible when heated above flash point. It will release flammable vapors which can burn in
open or be explosive in confined spaces if exposed to source of ignition.
STORAGE
:
Avoid storage near open flame or other
sources of ignition.
HOW TO USE THE G704B-SR
After selecting the proper pulling head and attaching it securely to Head Cylinder, connect the regulated airline to the too (if the tool is
equipped with a preset regulator P-1505, air source may be unregulated)l.
The riveter has a 4 food hose extension allowing it to reach into tight spaces. Hold the Head Manifold in one hand, having the Handle
Assembly in the other. If the area to access is close to the floor, the Handle Assembly may be placed on the floor.
To trigger, depress the button under the manifold.