P1444
TOOL OVERHAUL
Tool overhaul is needed in case of tool malfunction, massive fluid loss or as part of your routine maintenance program.
TOOLS NEEDED: G84-LSKT – tool kit,
Needle Nose Pliers,
G84-LSKS – service kit: complete seal and fastener set for tool overhaul
OVERHAUL PROCEDURE
Caution:
Maintenance and repair to be conducted only by trained personnel.
Prior to attempting any repair or maintenance work, make sure the air is disconnected.
Follow these instructions. Use special care handling sealing surfaces.
Apply an O-ring lubricant (Parker
®
silicone lube or equivalent) on all O-ring s.
After tool overhaul, fill with DEXRON III ATF fluid and bleed (see page 5).
AIR VALVE SUB-ASSEMBLY
Disassembly Instructions:
Remove retaining ring (56) and muffler (55).
Insert the valve plug extractor P1178 into the en d of valve plug (54) and pull it out.
Pull out the valve spool subassembly (86) the same way.
Note: In the unlikely event the valve sleeve (47) is irreversibly clogged, remove it as follows:
Grab one end of spring (49) with needle-nose pliers and turn/pull to dislodge it from it’s groove
After spring removal, pull out the valve sleeve (47) by using the removal tool 837B740.
Assembly Instructions: Reverse the above procedures.
Caution: Install valve sleeve (47) carefully with your fingers: gently push and wiggle it to allow
O-rings to slip in. Install spring (49); use tool 836B740 to push it firmly into the groove.
8 3 6 B 7 4 0
Valve Spring Installation Tool
P 1 1 7 8
Valve Plug Extractor
744-104
Seal Guide
744-195
530-202
7 0 0 A 7 7
Air Bleeder
G84-LSKT TOOL KIT
8 3 7 B 7 4 0
Valve Sleeve Removal Tool
700A61
Piston Rod Wrench
530-201
744-194
6
Содержание G84-LS
Страница 10: ...G84 LS CROSS SECTIONAL VIEW 10...
Страница 11: ...G84 LS EXPLODED VIEW 11...