FIRST AID
Skin:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention.
If irritation develops, consult a physician.
Ingestion:
Seek medical attention immediately. DO NOT INDUCE VOMITING.
Eyes:
Flush with copious amounts of water. If irritation develops, consult a physician.
Inhalation:
No significant adverse health effects are expected to occur on short term exposure. Remove from contaminated area.
Apply artificial respiration if needed. If unconscious, consult physician.
FIRE
Suitable extinguishing media:
CO
2
, dry powder, foam or water fog. DO NOT use water jets.
ENVIRONMENT
Waste Disposal:
In accordance with local, state and federal regulations.
Spillage:
Prevent entry into drains, sewers and water courses. Soak up with diatomaceous earth or other inert material.
Store the spent fluid in appropriate containers for disposal.
HANDLING
Eye protection required. Protective gloves recommended. Chemically resistant boots and apron recommended. Use in well ventilated area.
COMBUSTIBILITY
It is slightly combustible when heated above flash point. It will release flammable vapors which can burn in open or be
explosive in confined spaces if exposed to source of ignition.
STORAGE
Avoid storage near open flame or other sources of ignition.
HOW TO USE THE RIVETER
After selecting the proper pulling head and attaching it securely to the riveter, connect the tool to an air line. Recommended air
pressure is between 90 and 110 psi. Insert the rivet stem into the pulling head until the head of the rivet is in contact with the
nosepiece. This will ensure full engagement between the jaws and the rivet stem and preventing slippage.
Insert the rivet into the application and depress the trigger to activate the tool. Upon the release of the trigger, the stem will eject to
the rear of the tool when straight, pulling heads with no side eject feature are used. Other pulling heads (offset, right angle) will either
captivate the stem or allow stem removal through the front only. See the appropriate tooling sheet for the selected pulling head.
If unclear, contact a CHERRY® representative.
MAINTENANCE AND REPAIR
The G747 has been manufactured to give maximum service with minimum care. In order that this may be accomplished, the fol-
lowing recommendations should be followed:
1. The hydraulic system should be full of oil and free from air at all times.
2. Keep excessive moisture and dirt out of air supply to prevent wear of air valve, air cylinder and air piston.
3. Tool should be routinely inspected for oil leaks.
Use automatic transmission fluid Type “A” (no substitutes). CHERRY® recommends using Dexron® III ATF.
DEXRON III OIL SAFETY DATA
PROPERTIES
Specific gravity
0.863
Weight per gallon
7.18 lbs.
Open flash point
>200°C (392°F)