FR
EES
TANDING CLEARANCES 3.3
14
CHEMINÉES
PHILIPPE
RADIANTE 700
FREESTANDING
A: CLEARANCES TO 50MM SKAMOL BOARD
CLEARANCES USING A STEEL HEAT SHIELD
CLEARANCES TO COMBUSTIBLES
110mm*
100mm
200mm
900mm
1400mm
Hearth
Combustible Wall
Combustible W
all
50mm Skamotec Board
50mm Skamotec Board
50mm
Air
Gap
50mm Air Gap
350mm*
300mm
200mm
900mm
1400mm
Hearth
Combustible Wall
Combustible W
all
50mm Skamotec Board
50mm Skamotec Board
The Skamol boards should extend all the way to the ceiling from the hearth. When using Skamotec board with a 50mm air
gap behind, it must also be ventilated for natural air flow circulation, (refer to page 15 & 16 for ventilation requirements).
400mm
800mm
200mm
Hearth
Combustible Wall
Combustible W
all
1000mm
150mm
200mm
900mm
1400mm
Hearth
Combustible Wall
Combustible W
all
Brick/Hebel
Brick/Hebel
*100mm is measured from the appliance closest point when there are
no combustible materials behind the brick/hebel wall.
A minimum 110mm solid brick/hebel thick wall should
extend to the ceiling from the hearth.
NON-COMBUSTIBLE CEILING:
For freestanding installations where the ceiling height is
less than 3 metres from the hearth, a non-combustible
board must be used on the ceiling and must extend
1000mm in all directions from the flue outer casing,
unless forming an abutment with a wall. This can be
made of a minimum 8mm cement sheet or equivalent.
GLASS CLEARANCE:
A minimum 1500mm from the front
glass to any combustible surfaces must be maintained.
150mm
CORNER CLEARANCES:
The same rear clearance
as depicted in these illustrations applies from the two
furtherest back corner points of the fireplace to each
corner wall. Base/hearth size remains the same (page 13)
B: CLEARANCES TO 50MM SKAMOL BOARD + AIR GAP
CLEARANCES TO A SOLID BRICK OR HEBEL WALL
200mm
(100mm*)
(100mm*)
200mm
Hearth
Combustible Wall
Combustible W
all
90mm Air Gap
90mm
Air
Gap
90mm
Air
Gap
500mm
335mm
225mm
The double heat shield should be 2.5mm thick steel
with a 13mm air gap between each skin. The outer skin
must be raised 10mm above the hearth. The C shaped
internal shield must be 1105mm wide by 605mm deep
by 1230mm high. A full triple skin flue kit must be used,
see page 17
(Refer to page 13)
(Refer to page 13)
(Refer to page 13)
(Refer to page 13)
(Refer to page 13)
*All rear clearance measurements are measured from the units closest point
Содержание RADIANTE 700
Страница 25: ...5 MECHANISMS UNIT ASSEMBLY 5 1 MECHANISM GUIDE 26 5 2 ASSEMBLY 27 30 25 ...
Страница 37: ...7 MAINTENANCE 7 1 SERVICING GUIDE 38 7 2 TROUBLE SHOOTING 39 7 3 SPARE PARTS 40 37 ...
Страница 41: ...8 WARRANTY 8 1 WARRANTY POLICY EXTENDED WARRANTY 42 8 2 INSTALLER CHECKLIST FORM 43 41 ...