- 11 -
Maintenance
Shut down the device immediately should abnormal operation be detected.
Avoid sudden impacts and the lamp should be dedusted regularly.
It is normal for the flash tube to be warm when in use. Avoid continuous flashes if
unnecessary.
Maintenance of the flash must be performed by our authorized maintenance
department which can provide original accessories. The flash-tube is user-
replaceable. Replacement tubes can be obtained from the manufacturer.
This product, except consumables e.g. flash tube, is supported with a one-year
warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired by
professionals.
Disconnect the power when cleaning the unit or when changing the flashtube.
Changes made to the specifications or designs may not be reflected in this
manual.
Technical Data
Model
Max. Power
Guide No. (m ISO 200)
Vertical Rotation Angle
Horizontal Rotation Angle
Power Supply
Full Power Flashes
Recycle Time
Color Temperature
Flash Duration
Dimension
Net Weight
CL-360
360Ws (307.2 True WS)
GN:220 (10ft, ISO 200, with standard reflector)
Approx. 28mm flash coverage when operating on a
camera with the standard reflector
-15° to 90°
0 to 270°
Cheetah Lithium power pack L4500
450 (with Cheetah Lithium power pack L4500)
Approx. 0.05-4.5s (with Cheetah Lithium power pack)
5600±200K
1/300s-1/10000s
75*95*220mm (flash tube & reflector not included)
780g (flash tube & reflector not included)
Protection Function
Over-Temperature Protection
To avoid overheating and deteriorating the flash head, do not fire more than 75
continuous flashes in fast succession at 1/1 full power. After 75 continuous flashes,
allow a rest time of at least 10 minutes.
If you fire more than 75 continuous flashes and then fire more flashes in short
intervals, the inner over-temperature protection function may be activated and make
the recycling time about 10 to 15 seconds. If this occurs, allow a rest time of about
10 minutes, and the flash unit will then return to normal.
When the over-temperature protection is started, is shown on the LCD display.
Number of flashes that will activate over-temperature protection:
Power Output Level
1/1
1/2
1/4
1/8
1/16, 1/32
1/64, 1/128
Number of Flashes (Approx.)
75
100
200
300
400
500
the CL-Tx transmitter , and CL-Rx receiver will be wirelessly communicated to the
flash. Then you can press the camera shutter-release button to trigger the flash.
For full instructions on the use of CL series remote control, see its user manual.
When the flash unit receives wireless signals, is shown on the LCD display.
11. Sync Triggering
The Sync Cord Jack (9) is a
Φ3.5mm plug. Insert a trigger plug here and the flash
will be fired synchronously with the camera shutter.
12. PC Sync Triggering
Insert one end of a PC sync cable into the PC Sync Socket (
1
0) of the flash unit and
the other end into the PC Sync Socket on the camera. The flash unit will fire when
the camera’s shutter-release button is pressed.