USER'S MANUAL, NP10 AND NP20
CHECKPOINT SYSTEMS, INC. CONFIDENTIAL AND PROPRIETARY INFORMATION, FOR INTERNAL USE ONLY
Document No. 10071753
Rev. 00
Page 13 of 14
3.7
LED Board
Mechanical specs:
PCB Layers: 2
PCB Materials: FR4
Dimensions:
NP10 - 319.5mm X 12mm [12.58in X 0.47in]
NP20 - 156.0mm X 12mm [6.14in X 0.47in]
Features: 10 LEDs aligned in a row.
Each LED can illuminate in various colors, relying on 3 individual LEDs (Red, Green, and
Blue) inside each of the 10 PCB-mounted LEDs.
Electrical specs:
Connector port (1): 7-Pin Hirose connector
Required Cable (available as a FS spare): ^CABLE ASSY,LED NEO (10056250)
Power input rating: 24V / 60mA
3.8
Environmental
All the internal electronics shall meet or surpass the listed environment specifications:
Operating Temperature: 0° to + 60° C
Non-Condensing Relative Humidity: 5% to 95%
4.0
USING DMS TO APPLY SOFTWARE SETTINGS
Checkpoint DMS is
by-license-only
software, which will be used by field service,
engineering and manufacturing to set up NEO.
Tuning can be performed using DMS. Transmit Power and other critical settings are
checked/set with the help of Analog View and similar software features. DMS is also used
at the time System installation to pick the LED color, pattern and the sound file (.mp3)
played when the EAS Alarm Event occurs.
5.0
POWER SUPPLY REQUIREMENTS
NEO re24 VDC supplied at J6 or J14 of the EAS Sensor.
An external AC-DC converter power supply rated at 24VDC nominal, with 90W max.
power limiting feature, complying with IEC/UL 60950-1 2nd Ed.+Am1 and evaluated to
clause 2.5 (LPS) of the mentioned standards is required. Only use 1 power connector as