background image

QUICK

 

SETUP 

Series ATP 

www.cppumps.com 

Tool Requirements 

Hex Wrenches: 1/8”, 5/32”, 3/16”

 

Open-

End Wrenches: 7/16”, 5/8”, 7/8”, 1”

 

Leg Assembly and Pump Attachment 

1. Unpack pump stand assembly, and ensure that all pieces are

supplied.

2. Place pump bracket (ATP0090-01) onto both legs. The four holes

near the edge of the bracket are located between the two legs (as
shown below).

3. Install the two rear bolts with washers through the pump bracket and

legs of the pump stand, and tighten the hex nuts.

PART # 

DESCRIPTION 

QTY. 

ATP0090-01 

PUMP BRACKET 

HHBS8042028 

HEXHEAD BOLT 

HHNIS80420 

HEX NUT 

HWSHS804 

FLAT WASHER 

PST0002-1 

LEG 

 SOLAR 

WARNING:

 

Ensure that you are wearing proper PPE before performing any action. 

WARNING:

 

Pinch points. Disconnect power before removing cover. 

4. Remove the front cover from the pump drive.
5. Set the pump on the stand such that the four carriage-assembly bolt-

heads line up in the stand clearance holes. Install the two front bolts
with washers from the underside of the pump through the legs and
into the pump drive housing, and tighten hex nuts.

6. Connect the suction line to the bottom check valve, and connect the

discharge line to the top check valve.

CP-QS-ATP

 REV00                                                 EFF. DATE: 1/9/2019

 Page 1 of 2