QUICK
SETUP
Series ATP
www.cppumps.com
Tool Requirements
Hex Wrenches: 1/8”, 5/32”, 3/16”
Open-
End Wrenches: 7/16”, 5/8”, 7/8”, 1”
Leg Assembly and Pump Attachment
1. Unpack pump stand assembly, and ensure that all pieces are
supplied.
2. Place pump bracket (ATP0090-01) onto both legs. The four holes
near the edge of the bracket are located between the two legs (as
shown below).
3. Install the two rear bolts with washers through the pump bracket and
legs of the pump stand, and tighten the hex nuts.
PART #
DESCRIPTION
QTY.
ATP0090-01
PUMP BRACKET
1
HHBS8042028
HEXHEAD BOLT
4
HHNIS80420
HEX NUT
4
HWSHS804
FLAT WASHER
8
PST0002-1
LEG
–
SOLAR
2
WARNING:
Ensure that you are wearing proper PPE before performing any action.
WARNING:
Pinch points. Disconnect power before removing cover.
4. Remove the front cover from the pump drive.
5. Set the pump on the stand such that the four carriage-assembly bolt-
heads line up in the stand clearance holes. Install the two front bolts
with washers from the underside of the pump through the legs and
into the pump drive housing, and tighten hex nuts.
6. Connect the suction line to the bottom check valve, and connect the
discharge line to the top check valve.
CP-QS-ATP
REV00 EFF. DATE: 1/9/2019
Page 1 of 2