3

1.2

Guide to Symbols

1.3

Unpacking

Main Unit × 1

Ring Sensor × 1

Cable × 1

User Manual × 1

Symbol Description

Type BF-Applied Part
Manufacturer
European authorized representative

CE0197

CE Marking indicating conformance to

EC directive No. 93/42/EEC concerning

medical devices.

MRI unsafe. Presents hazards in all MR

environments as device contains

strongly ferromagnetic materials.

Indicate separate collection for electrical

and electronic equipment (WEEE).

IP22

Protected against spraying water and

against access to hazardous parts with a

tool, per IEC 60529.
Follow Instructions for Use.

Warning and Caution!

SN

Serial number
No alarm system.

Содержание Max

Страница 1: ...Checkme O2 Max Smart Wrist Pulse Oximeter User Manual ...

Страница 2: ...User s Manual Contents 1 Introduction 1 2 Using the Monitor 4 3 PC software 8 4 Maintenance 9 5 Troubleshooting 9 6 Specifications 10 7 Electromagnetic Compatibility 11 ...

Страница 3: ...r doctor for any health condition Warnings and Cautionary Advices DO NOT squeeze the sensor or apply excessive force on the sensor cable Do not use this device during MRI examination Never submerge the device in water or other liquids Do not clean the device with acetone or other volatile solutions Do not place this device in pressure vessels or gas sterilization device Consult your doctor immedia...

Страница 4: ...ently Functional tester cannot be used to assess the accuracy of a SpO2 sensor or a device This device is designed to determine the arterial oxygen saturation percentage of functional hemoglobin Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following excess ambient light excessive motion electrosurgical interference blood flow restrictors...

Страница 5: ...to EC directive No 93 42 EEC concerning medical devices MRI unsafe Presents hazards in all MR environments as device contains strongly ferromagnetic materials Indicate separate collection for electrical and electronic equipment WEEE IP22 Protected against spraying water and against access to hazardous parts with a tool per IEC 60529 Follow Instructions for Use Warning and Caution SN Serial number ...

Страница 6: ...Pulse oximeter 2 Wristband 3 Sensor interface charging interface 4 Power button 5 SpO2 sensor Screen display item description SpO2 Pulse rate Wear the sensor Time Remaining battery capacity Alert is on Alert is off Bluetooth is connecting ...

Страница 7: ...cally power off The device will turn off automatically in 2 minutes if no measurement no operation or without App connection Manually power off You can press the button for about 2 seconds to turn off 2 4 TAKE THE FIRST RECORDING START Wear the device and the Ring Sensor press the button to power on And keep yourself in the quiet environment For the sake of clarity recommended the user wear the mo...

Страница 8: ... the sensor again the record will be resumed After the countdown the data will be ready for sync Note The duration of the recording is 1mins 10 hours And the device can collect and store maximum 4 recording when the 5th recording coming the first recording will be will covered Sync data to the ViHealth App You can Sync the data to your app after the countdown or next time after you turn on the dev...

Страница 9: ... Note Refer the ViHealth app manual for more details 2 7 Alert When the monitor detects low blood oxygen or abnormal pulse rate it supports triggering vibration reminders or sound reminders You can customize the vibration reminder after the monitor power on or use the App to configure the vibration intensity The sound reminder only can be configured on the App 2 8 Download App App name ViHealth iO...

Страница 10: ...ownload the PC Software PC Software O2 Insight Pro Download from www viatomtech com support Install the software on Windows PC or Mac 3 2 How to connect the monitor to PC 1 Turn on device connect the device to PC USB port with the supplied Cable of data 2 Open the PC software download data from the device 3 With the optional PC software You can view and print report which can also be exported as P...

Страница 11: ...ohol to clean the device surface 4 2 Battery To keep the battery in good condition charge the battery every 6 months when the device is not in use 5 Troubleshooting Problem Possible Cause Possible Solution Device does not turn on or no response Battery may be low Charge battery and try again Unexpected software condition Press the button for about 10 seconds to reset Device might be damaged Please...

Страница 12: ... BLE Vibrator Built in Power Supply Charge input DC 5V 10 Battery type Rechargeable lithium polymer battery Battery run time 72 hours Charge time 2 5 hours SpO2 Standards Meet standards of ISO 80601 2 61 Measurement accuracy verification The SpO2 accuracy has been verified in human experiments by comparing with arterial blood sample reference measured with a CO oximeter The pulse rate accuracy has...

Страница 13: ...eased electromagnetic immunity of the equipment The device or its components should not be used adjacent to or stacked with other equipment The device needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided below Other devices may interfere with this device even though they meet the requirements of CISPR When the inputted sig...

Страница 14: ...12 https api viatomtech com cn documents 2017 emc_en pdf ...

Страница 15: ... 518100 Shenzhen P R China www viatomtech com MedNet GmbH Borkstrasse 10 48163 Muenster Germany Tel 49 251 32266 0 Fax 49 251 32266 22 2020 11 Version A Contents of this manual are subject to changes without prior notice Copyright 2020 Shenzhen Viatom Technology Co Ltd All rights reserved Model Oxiband ...