background image

     

EXT     External trigger Input 

ON  

Switch on button 

OPERATION The Use of Internal Trigger 

Turn the power on. The system enters the internal trigger mode. Turn 

the  encoder  knob,  or  press  the  “+”  “-”  keys  to  adjust  the  strobe 
frequency or flash speed so that detected the object appears stationary. 
Use “× 2” “÷ 2” keys to make large changes to the flash frequency. 

To measure true revolutions per minute (RPM) by Marking:  

1.

 

“Mark”  the  object  to  be  measured  by  either  visually  noting  an 
inherent distinguishing characteristic (such as a label, scratch, etc.) or 
physically marking the object with a small piece of tape, pencil mark, 
etc.  If the object has a uniform shape, such as multi blade fan or the 
shaft of a motor, you should give it an identifying mark with reflective 
tape or paint to distinguish its direction. 

2.

 

Turn power switch on.   

3.

 

Set flash rate to the highest value and adjust downward.  

4.

 

The true RPM can be noted once the action appears frozen and the 
first  single  image  of  the  “mark”  appears  (see  chart  below  and 
accompanying diagram for further explanation).  

5.

 

To  verify  RPM  reading,  press  “÷2”;  a  single  image  should  appear 
again.   

 

To measure true revolutions per minute (RPM) without Marking: This 

example explains that if the object has a suitable, unique shape, then 
the  actual  speed  of  the  object  may  not  need  to  be  determined  by 
marking the object.   

In this example, the rotation is below 7000 rpm, the following harmonic 

image appears: 