13
PEAK HOLD MODE OPERATION
Red LED
Approached Target Torque
Buzzer
((((((((
)))))))) (((((((
)))))))
Reach Target Torque
Current Torque Value
(Peak Hold)
START
(System initial)
Apply Torque
Note:
1. If
is appeared, that means this wrench has ever
been applied more than 110% of torque of the spec
2. If
is appeared, that means the wrench’s memory is
full and the next value record can not be written in. Please
refer the “Peak Hold Mode Recorded Value Review” section to
clear the momory records.
3. The green LED will be on for 80%, 85%, 90%, 95% and
97.5% of target torque.
4. When reaching the target torque, the green and red LED will
be on at the same time.
*Note 1
((…((…
…))…)) ((…((… …)) …))
Buzzer
Green LED
Reach 80% of Target Torque
Flashing
Apply Torque
Released
Setting Target Torque
*Note 4
Reach 80% of Target Torque
Recording
*Note 2
*Note 3