Introduction
26000 and 28000 Appliances Getting Started Guide | 44
PSU Configuration and Monitoring
These are the supported PSU configurations for the 26000 appliance models and PSU types:
PSU Type
26000 Base
26000 Plus
26000 Turbo/
28000 Base/Plus
28600HS
AC/DC PSU
3 PSUs
3 PSUs
3 PSUs
2 PSUs
Important
- All PSUs on an appliance must be of the same type, either all AC or all DC.
When a PSU functions correctly: the PSU LED is green, the Alert LED is not blinking due to a PSU issue
(might still be blinking due to other errors), and there is no SNMP alarm.
When a PSU does not function correctly: the PSU LED is amber, the Alert LED is blinking due to a PSU
issue, and an SNMP alarm is sent.
To monitor the PSUs through the
CLI
:
1.
Connect to the command line on the appliance.
2.
Log in to
Gaia Clish
.
3.
Run:
show sysenv ps
Sample output for a 26000 Turbo appliance:
Where:
Column
Description
Name
Power Supply #1
- The PSU in the top PSU slot.
Power Supply #2
- The PSU in the middle PSU slot.
Power Supply #3
- The PSU in the bottom PSU slot.
Value
Up
- The PSU slot contains a PSU and is up.
Down
- The PSU slot contains a PSU and it is not connected to a power source.
Empty
- There is nothing in the PSU slot.
Dummy
- The PSU slot contains a dummy filler (only supported for 1 PSU slot in
26000 Base/Plus.
Unit
Up/Down
- The type of measure unit used for PSUs is either Up or Down.