Electromatic Equipment Co., Inc. 

-8- 

6.0 

CHANGING BATTERIES 

 
 
Your new device is provided with batteries. 
 
Change of batteries: 
 
1.   Press  with  your  finger  onto  the  arrow  of  the  battery 

cap and pull it back. 

 

2.   Remove the empty batteries. 

 

3.   Put  four  new  batteries  in  the  device.  Make  sure  the 

position of the battery poles is correct. 

 

4.   Press down the batteries and close the cap.  
 
 
 
 

7.0 

DETERMINATION OF THE MATERIAL REFERENCE MOISTURE 

 
 

The principle is a comparison measurement with the dehydration method according 
to  CEN/TS  14774.  Take  the  measured  sample  and  weigh  it.  Dry  it  out  in  an  oven 
and weigh it again. 
 
 

 

 
M

: Mass with average moisture content 

M

t

   : Mass of the dried sample 

%F  : Calculated absolute moisture 
 
 

Exemption from liability 

 
For miss-readings and wrong measurements and of this resulting damage we refuse 
any  liability.  This  is  a  device  for  quick  determination  of  moisture.  The  moisture 
depends on multiple conditions and multiple materials. Therefore we recommend a 
plausibility  check  of  the  measuring  results.  Each  device  includes  a  serial  number 
and  the  guarantee  stamp.  If  those  are  broken,  no  claims  for  guarantee  can  be 
made. In case of a faulty device, please contact Electromatic. 

 

%F =

               

x 100

  

M

n

 - M

M

 

Electromatic Equipment Co., Inc. 

-9- 

8.0 

TRANSFER SAVED DATA TO THE PC 

 
 
(Only possible with humimeter serial interface module) 

 
To  send  your  saved  logs  to  your  PC,  connect  the 
humimeter-device  to  your  PC  using  the  cable  that 
was  delivered  with  your  device.  You  can  either 
connect  it  directly  to  a  serial port  on  your  PC  or  use 
the enclosed serial-USB adapter.  
 
 
Start the LogMemorizer software on your PC. 
 
 
For installation and the required settings, please have 
a look at the separate LogMemorizer manual.  
 
 
 
 
 
 

Press the 

-key until you reach the menu (as in the 

image  on  the  right).  Then  choose  „Send  Logs“  from 
the menu and confirm with 

 
 
 
Now you can choose “Manual Logs” and confirm with 

 again. The selected Logs will be sent to your PC. 

If  no  transmission  is  performed,  please  check  your 
cable connection and the LogMemorizer settings and 
try again. 
 
 
 
If  your  device  supports  online-sending,  this  can  be 
activated  in  the  menu  „Options“.  If  the  option  is 
active,  every  newly  recorded  log  will  immediately  be 
sent to your PC. 

 
 
 
 
 

Содержание BP1

Страница 1: ...cedure 3 3 0 Calibration curves 5 4 0 Menu level overview 6 5 0 Keypad symbols 7 6 0 Changing batteries 8 7 0 Determination of the material moisture 8 8 0 Transfer saved data to the PC 9 9 0 Print saved data 11 10 0 Technical data 12 11 0 Most common reasons for miss readings 13 12 0 Device maintenance instructions 13 13 0 Warranty 14 ...

Страница 2: ...nc 2 1 0 DESIGN OF THE DEVICE Batteries slot flipside Measuring chamber Optional PC interface Name of calibration Moisture content POWER button Filling assistance Change the calibration curve Electromatic Equipment Co Inc 15 NOTES ...

Страница 3: ...s do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you The duration of any implied warranty including without limitation fitness for any particular purpose and merchantability with respect to this product is limited to the duration of the foregoing warranty Some states do not allow limitations on how long an implied warranty l...

Страница 4: ...rage area usually creates condensed water which may lead to major measuring errors Not adjusted pellets Let your humimeter BP1 adjust to the surrounding temperature of the material for approximately half an hour A very high temperature difference has a negative effect on the stability of the measurement result Wrong calibration curve Before you measure your sample double check the correct selectio...

Страница 5: ...ring range limits 280g wood pellet 280g 3 up to 20 250g spec pell 1 250g 3 up to 20 250g spec pell 2 250g 3 up to 20 250g spec pell 3 250g 3 up to 20 reference Explanation of the curves 280g wood pellet To analyze the moisture of Ø6 and Ø8 mm wood pellets with a maximum length of 30mm According to norm CEN TS 14961 If you do not want to measure wood pellets or wood pellets with smaller bulk densit...

Страница 6: ...rial interface module in combination with Schaller thermo printer To print your saved logs connect the printer to the humimeter serial interface using the cable that was delivered with your device To switch on the printer press the ON OFF button If the printer is correctly switched on the green LED blinks regularly If it does not replace the batteries and try again Press the key until you reach th...

Страница 7: ...ow the port number COM1 COMX You can find this setting in the device manager directory ports COM LTP See print screen below The shown port number in the device manager COMx in our example COM6 for the USBRS232 adapter has to be selected in the software humimeter LogMemorizer directory Extras Settings Device Close the dialog using the button OK Electromatic Equipment Co Inc 7 5 0 KEYPAD SYMBOLS Mea...

Страница 8: ...ring results Each device includes a serial number and the guarantee stamp If those are broken no claims for guarantee can be made In case of a faulty device please contact Electromatic F x 100 Mn Mt Mn Electromatic Equipment Co Inc 9 8 0 TRANSFER SAVED DATA TO THE PC Only possible with humimeter serial interface module To send your saved logs to your PC connect the humimeter device to your PC usin...

Страница 9: ...BP1 PELLET MOISTURE METER OPERATING INSTRUCTIONS Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net ...

Отзывы: