chazelles A5CN Скачать руководство пользователя страница 9

A5CN 

– A6 – A8 

(Rev. 01/06/2012)                                                                                                                            

ENG

      

9

 

 

 

3. HANDLING AND STOCKING 

The cardboard/wood package has been designed to protect the 

stove  but  cannot  be  stocked  outside  or  in  very  damp  places.  It 
must be exposed to the elements, otherwise some components 
or  the  stove  itself  could  get  damaged  and  the  guarantee  will 
decline.  As  stoves  have  some  fragiles  parts  like  glasses  and 

electronic components, it should be handled following few basic 
rules: 
Lift and lay down the stove gently. In case you use a two wheels 
trolley or when transporting upstairs, always take the stove at the 

side opposite to the glass (which is identified by a sticker). The 
glass is always placed on the sticker side. 

 

 
 
 

 

4. AUTHORIZED FUEL 

Pellet is produced with wood rests from clean wood machining like sawmills, furniture manufacturing or new wood 
from forest culture. All these 100% vegetable materials are dried and pressed into the pellet form without adding any 
kind of glue or chemical. We do approve to be used in our stoves all pellets that satisfy the European regulation EN 
14961-2. All the approved pellets must carry the following logo:

 

 

New logo since 2011 

 
 
Typical specifications for the approved fuel: 
 

.caloric capacity (in MJ/kg) (2*) 

. ≥ 17,6 MJ/kg 

.caloric capacity (in KWh/kg) (2*) 

≥ 4,9 KWh/kg 

.caloric capacity (in Kcal/kg) (3*) 

≥ 4.223 Kcal/kg 

..density 

..1,12 kg/dm3 

..water content 

..mass. 10,0 % 

..ash content 

..mass. 0,5 % 

..length 

..mass. 30 mm 

..diameter 

5- 6 mm 

..thin material (rests) 

..mass. 2,3% (1*) 

..composition 

..natural wood 

 

If using a low quality fuel, the stove could possibly work not properly and can lead the guarantee to decline.  
The uses of low quality pellet leads to: 
-  Shorter cleaning intervals  
-  Higher fuel consumption  

-  Lower output  
-  Glass getting quickly dirty  
-  Fire pot and exhaust smoke connection will clog up rapidly 
 

5. NON AUTHORIZED FUELS 

All pellet types that doesn’t satisfy the a.m. indications.. 

 

 

Содержание A5CN

Страница 1: ...A5CN A6 A8 Rev 01 06 2012 ENG 1 Installation and instruction manual Pellet stoves Mod A5CN A6 A8...

Страница 2: ...2 ENG A5CN A6 A8 Rev 01 06 2012 DIMENSIONS AMANDINE ADELAIDE ADELE ALESSIA ANTONELLA AXELLE ALEYNA ARMELLE ALINE...

Страница 3: ...A5CN A6 A8 Rev 01 06 2012 ENG 3 A 200 mm B 300 mm C 800 mm D 500 mm E 300 mm B B A D C E...

Страница 4: ...4 ENG A5CN A6 A8 Rev 01 06 2012 B B A D C E A 200 mm B 300 mm C 800 mm D 500 mm E 300 mm...

Страница 5: ...A5CN A6 A8 Rev 01 06 2012 ENG 5 B B A D C E A 200 mm B 300 mm C 800 mm D 500 mm E 300 mm...

Страница 6: ...ars for all or gas stoves At the end of the production we do connect and fire all stoves and thanks to a special electronic control do simulate all the typical conditions like in your everyday use In...

Страница 7: ...ELECTRICAL CONNECTION 16 16 REMOTE CONTROL INSTRUCTIONS 17 17 LIST OF MENUS 18 18 MENU 02 DAY AND TIME SETTING 19 19 MENU 03 SET WALL THERMOSTAT 19 20 MENU 04 SELECT LANGUAGE 21 21 MENU 05 SET ROOM T...

Страница 8: ...ke that could develop will rapidly fade away Regular maintenance and cleaning are essentials for the stove proper working and lasting Check for craked or broken glasses In case replace immediately You...

Страница 9: ...ulture All these 100 vegetable materials are dried and pressed into the pellet form without adding any kind of glue or chemical We do approve to be used in our stoves all pellets that satisfy the Euro...

Страница 10: ...ber Inner glass ceramic Closing door Door Charge pellet in fire pot Interior in skamolex Convection air outlet Overpressure security valve Handle opening door Make sure the power supply is always avai...

Страница 11: ...t it against radiant heat and eventually some combustion rests with appropriate non flammable materials steel marble tiles etc Minimum distances to be respected are shown below and in the first page o...

Страница 12: ...om flammable materials The chimney has to be built in accordance with the local and national regulations in force 10 CONNECTING TO THE EXISTING SMOKESTACK The connection to the existing smokestack has...

Страница 13: ...ack height Always follow the local and national regulations in force CONNECTOR T WITH CAP A HERMETIC CLOSING CONNECTOR 80 100 80mm 100mm STOVE INSULATING CONNECTOR T CONNECTOR T CLEANING DIRECTION CLE...

Страница 14: ...ll the following cases All outside smokestacks When getting through non heated attics or mansards Very long segments over 4 meters inside the apartment INSULATING INSULATING CLEANING DIRECTION Max 4 m...

Страница 15: ...LE CEILING Be very careful when getting through walls ceilings or roofs made of flammable materials The high smoke temperatures can start a fire Always respect the safety distances of your local and n...

Страница 16: ...NECTION Check that the wall plug is in accordance to the stove electrical requirements 230V 50Hz e 400Watt Make sure that the electrical cord doesn t get in touch with any hot part of the stove and do...

Страница 17: ...een If no buttons are pressed for 30 seconds after switching on the stove the remote control enters the stand by status and the display goes off Press any button to reactivate To lock or unlock the ke...

Страница 18: ...ram 1 OFF 00 00 24 00 Stop program 1 OFF 00 00 240 00 10 minutes interval MENU 04 SET LANGUAGE Italian ITA French FRE English ENG German DEU MENU 05 SET PROBE Inside probe Remote control probe MENU 06...

Страница 19: ...3 Press button 2 for changing year 24 Press button 7 to confirm and then button 3 19 MENU 03 SET WALL THERMOSTAT This program enables you setting a fire or power off interval for each week day You can...

Страница 20: ...switch off time is displayed 19 Press button 2 for changing switch off time 10 minutes steps 20 In this example switch off time at 09 00 AM is shown 21 Press button7 to confirm switch off time 22 Firs...

Страница 21: ...he menu 3 The selected language is displayed ENG English 4 Press button 2 for selecting the desired 5 Press button 7 to confirm 6 Press button 3 to back the menu 21 MENU 05 SET ROOM TEMPERATURE PROBE...

Страница 22: ...on beep for all remote control operations 1 Select menu 07 button 7 and then button 2 2 Press button 7 to enter the menu 3 The OFF or ON setting will be displayed 4 Press button 2 to select the settin...

Страница 23: ...fan disabled fan goes however automatically on in case of overheating over 250 C in order to cool the stove down within safety parameters than the fan goes automatically off 1 Select menu 12 button 7...

Страница 24: ...utton 1 for decreasing temperature 4 Press button 2 for increasing temperature 5 Press button 7 to confirm 6 Press button 3 to back to main menu 31 POWER SETTING Desired power level can be set from 1...

Страница 25: ...r stove s panel 5 Switch the stove on by mean of the main switch located on the rear stove s panel 6 Press red button 3 7 UNIT 1 LOADED or unit 0 or 1 or 2 or 3 will be displaye 8 After some 10 the re...

Страница 26: ...vant green led starts flashing When the self clearing procedure will be finished it goes out Covering led This led confirms the remote control transmission has been correctly covered Alarm Led This le...

Страница 27: ...re pot grid being properly located Check the door being properly closed FUEL LOADING Swing the flap door located on the upper panel up Cut a corner of the bag of and let pellet slowly flow into the ta...

Страница 28: ...c glass cleaner PULISCI VETRI Make sure air adduction slots being free and clean Every year Combustion chamber Lower smoke chamber Smoke fan Connection pipe to the smokestack Fan if fitted Air intake...

Страница 29: ...ditional probe ambient 230V Ground fan smoke cochlea main interchange electrical resistance yellow green Blue Pink White White Violet Green Gray Brown Red Gray Orange Orange ALF Safety thermostat Gene...

Страница 30: ...re probe failure On board temperature probe failure Solution detect the causes To quit the error signal follow the procedure 1 Unscrew protection cup 2 press safety thermostat button 3 screw the prote...

Страница 31: ...ough the a m possible causes If doesn t solve the problem call for technical service Problem the stove doesn t copy the remote control Cause check the main switch on stove s rear panel being ON check...

Страница 32: ...the stove guides 2 Guide the corner up to the support bottom 3 Remove two silicone rubber from the packaging 4 Paste the rubber at either end of the angle ceramic 5 Place the second angular ceramic 6...

Страница 33: ...the ceramic side up to the support bottom 3 Remove two silicone rubber from the packaging 4 Paste the rubber at either end of the lateral ceramic 5 Place the second side ceramic 6 Paste the rubber at...

Страница 34: ...s are eluding from the guarantee 8 3 3 all ceramic components are handmade Small marks or differences in color cannot be considered as failures but a plus being the sign are made one by one as per a c...

Страница 35: ...A5CN A6 A8 Rev 01 06 2012 35...

Отзывы: