27
1. PRESENTATION
Clamp multimeter F05 emphasises reliability and simplicity
of use to respond to the needs of power professionals:
■
A compact unit integrating the current sensor for intensity
measurements without breaking the test circuit
■
Outstanding ergonomic features, in particular:
- automatic or manual selection of the type of signal to be
measured, AC or DC,
- automatic selection of measurement calibre,
- programmable audio voltage indication: V-Live,
- “measurement range exceeded” indication,
- Backlighting of the digital display
- auto power off system,
- MIN - MAX – PEAK value recording function,
- correction of deviations in DC measurement (DC zero)
- automatic compensation of measurement cable
resistance (
Ω
zero).
■
Compliance with CEI electrical safety standards and CE
markings
■
Lightness and ruggedness for field use
With all new additional features:
■
“Inrush” function in particular for measurement of motor
starting currents.
■
Phase order indication function using “2-wire” technique -
PFISTERER
Licence
- (instead of 3-wire) capable of
determination through contact only, with no fastidious
connections.
2. DESCRIPTION
(see diagram in § 8 Appendix)
➀
➀
➀
➀
➀
Jaws
➁
➁
➁
➁
➁
6-way rotary switch:
OFF
Deactivation of the clamp, activation is ensured by
selection of other functions
V
Measurement of DC and AC voltages (rms value)
Continuity measurement, by use of the yellow
resistance key and semi-conductor test
A
Measurement of DC and AC voltages (rms value)
W
~
Measurement of active power in one phase and of
power factor
1
2
3
Selection of phase order indicator for 3- phase
system with or without neutral