63
Press again to stop recording MIN, MAX and AVG values :
- The
HOLD
and
PAUSE
symbols disappear.
- The digital display indicates the current measurement or the contents of the MIN, MAX or
AVG registers on read mode.
- The instrument is again on MIN, MAX and AVG mode but the registers have not yet been
reinitialised and they contain the MIN, MAX and AVG values present before HOLD was used.
When the
HOLD
and RECORD-PAUSE symbols are displayed, it is also possible to cycli-
cally display the values recorded and the instantaneous measurement by short presses on
(see the sequence diagram below).
The analogue display always shows the value of the current measurement.
MIN MAX
MIN MAX
MIN MAX
MIN MAX
MIN MAX
▼
▼
Whatever the position of the display :
- one press on stops the recording without reinitialising the memories.
- one press on for more than 2 seconds cancels the record function.
Remark :
In normal measurement (without recording, so without
RECORD
symbol) if, after having
pressed , the user starts recording by pressing and if the readout
of the contents of the MIN or MAX or AVG memories is needed during this
HOLD
, the display
will show three hyphens - - -, the contents of these memories will not be significant because
the instruction to record was made during the
HOLD
function, which blocks the reinitialisation
of these memories.
ALARM ON/OFF
When the thresholds are programmed, press to switch on detection of crossing
these thresholds.
59
HOLD
Displayed value
Symbols displayed
HOLD value
HOLD
RECORD-PAUSE
¥
(time of recording)
MAX value
MAX
RECORD-PAUSE
¥
(time of recording)
MIN value
MIN
RECORD-PAUSE
¥
(time of recording)
AVG value
AVG
RECORD-PAUSE
∆
t (duration of averaging)
Current measurement
RECORD-PAUSE
¥
(present time)
MIN MAX
HOLD
HOLD
ALARM
MIN MAX
MIN MAX