10
3. CHARACTERISTICS
3.1 CHARACTERISTICS OF CONSTRUCTION
Housing
black plastic rigid shell
Dimension
103 x 64 x 28 mm
Mass
approx. 200 g
3.2 ELECTRICAL CHARACTERISTICS
Input
230 V AC / 50 Hz / 30 mA AC / 6.9 V A
Output
9 V DC / 150 mA DC / 1.35 W
3.3 ENvIRONMENTAL CONDITIONS
The adapter must be used in the ollowing conditions:
Use
indoors
Level o pollution
2
Altitude
< 2000 m
3.4 COMPLIANCE WITH INTERNATIONAL STANDARDS
This instrument complies with the sa ety standard IEC 61010-1 (Ed. 2 o 2001) or 300 V installations in
category II on the mains supply side and up to 600 V in category III on the measurement device side.
Note:
The installation o the mains adapter does not change the standardised sa ety characteristics indicated
or the measurement device only. Below are the characteristics o the electrical housings:
Type o device
Standardised characteristics
Series K
300 V CAT II
Series MA100
600 V CAT III
Series MA200
Series Amp
FLEX
A100
4. MAINTENANCE
To clean the mains adapter, proceed as ollows:
Disconnect everything connected to the device and set the switch to OFF.
Use a so t cloth, dampened with soapy water. Rinse with a damp cloth and dry rapidly with a dry cloth
or orced air.
Содержание AmpFlex A100
Страница 27: ......