2006-01-27 5:37:23 PM

 

230V

110V

5A

CH. 1

MAX.LOAD

MAX.LOAD

MAX.LOAD

MAX.LOAD

110V 550W

110V 550W

110V 550W

110V 550W

230V 1150W

230V 1150W

230V 1150W

230V 1150W

5A

CH. 2

5A

CH. 3

5A

CH. 4

POWER INPUT

15 

Amp 

Max 

No more than a 

combined

 1700 watts in 120V AC 

and 3400 watts in 230V AC should be connected to 
the Stage 4. Exceeding this amount may cause the 
device to abruptly trip its 15 Amp circuit breaker. 
 

O

PERATING 

I

NSTRUCTIONS 

 

Setup 

Although lighting fixtures with or without motors can be connected to the Stage 4 it is important to 

avoid dimming fixtures with motors. Only use the faders to dim parcans, pinspots or fixtures without 

internal motors.  

 

 

 

 

 

Operation 

1) 

The Stage 4 is a plug and play controller pack. Simply connect your lighting fixtures to the 
outlets in the rear and turn the power switch on. 

2) 

Choose a chase program by turning the (5) position rotary knob. 

3) 

Adjust the Sound Sensitivity knob to enhance the playback of the chase while in a sound 
activated chase program. Likewise, adjust the Speed knob while in any other chase program.  

4) 

If chasing conventional lighting, use the channel faders freely to adjust intensity of the lights.  

5) 

Press the FULL ON button to cease the chase and turn all lights permanently on. Channel 
faders continue to function and in this setting the Stage 4 can be used as a regular dimmer pack.  

6) 

Press the BLACK OUT button to stop all output from the Stage 4. All lights will turn temporarily 
off until the button is pressed again.  

Содержание TFX-DC4

Страница 1: ...929 5560 www chauvetlighting com TFX DC4 Stage 4 Controller USER MANUAL ON OFF SOUND SENSITIVITY SOUND SENSITIVITY SPEED FULL ON BLACK OUT STA GE 4 CH 1 CH 2 CH 3 CH 4 MIC FUSE 5A FUSE 5A FUSE 5A FUSE 5A POWER MIN MAX MIN MAX CHASE CHASE SOUND 16 PATTERNS AUTO FLASH 16 PATTERNS SOUND ...

Страница 2: ...3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 AC POWER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 GENERAL OVERVIEW 4 PRODUCT OVERVIEW 5 OPERATING INSTRUCTIONS 6 SETUP 6 OPERATION 6 APPENDIX 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 7 TECHNICAL SPECIFICATIONS 8 ...

Страница 3: ...voltage you will use Warning Verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the prop...

Страница 4: ... outlets on board General Overview The TFX DC4 is a very easy to use 4 channel chaser switch pack that also doubles as a 4 channel dimmer Five preset programs can be selected instantly from an on board rotary switch The programs consist of a chase sound chase two programs with 16 patterns each that can be executed in both auto and sound modes and a flash program The Stage 4 can be set to either Fu...

Страница 5: ...anently to fader control or all on 6 Blackout button Temporarily shuts off all output from the pack 7 Mic Internal microphone used during sound chase mode 8 Sound sensitivity knob Adjust the microphones sensitivity for optimum performance 9 Speed knob Adjust chase speed when not set to a sound mode 10 Chase select knob Select any one of the five built in chase programs 1 2 3 4 5 6 7 8 9 10 230V 11...

Страница 6: ...res without internal motors Operation 1 The Stage 4 is a plug and play controller pack Simply connect your lighting fixtures to the outlets in the rear and turn the power switch on 2 Choose a chase program by turning the 5 position rotary knob 3 Adjust the Sound Sensitivity knob to enhance the playback of the chase while in a sound activated chase program Likewise adjust the Speed knob while in an...

Страница 7: ...eported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise General Troubleshooting Applies to Symptom Sol...

Страница 8: ... in Width 130 mm 5 13 in Height 70 mm 2 75 in Weight 1 7 Kg 3 76 lbs POWER Switch selectable power setting 110V 60Hz or 230V 50Hz THERMAL Maximum ambient temperature 45 C 113 F FUSE Output 4 20mm Glass 5A Fast Blow Main 15A Resettable circuit breaker ORDERING INFORMATION Stage 4 TFX DC4 Fuse 5A P170FUSE005 ...

Отзывы: