Chauvet Stage Dimmer 12 Скачать руководство пользователя страница 14

  

Appendix 

TFX-D12 User Manual 

14  

2004-11-11/11:32 

 Maintenance 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build can cause overheating. Be sure to power off fixture 

before conducting maintenance. 

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components. 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products 

returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause 

for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate 

packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to 

repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe 

method to use. 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise.  

Содержание Stage Dimmer 12

Страница 1: ...h Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2004 11 11 11 32 TFX D12 Stage Dimmer 12 USER MANUAL UP MENU DOWN ESC DMX 1 2 CH DIGIT ALMODULE DIMMER...

Страница 2: ...Control Wiring 7 DMX512 7 Analog 0 10VDC 7 OPERATING INSTRUCTIONS 8 START MENU 8 MENU NAVIGATION 8 Setup Menu 9 DMX Fail Dmx fail 9 Hold Analog 9 Prog 01 12 9 Phase Correction Pha corr 10 DMX Address...

Страница 3: ...risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate vent...

Страница 4: ...dles Forced air cooling DMX Signal Indicator 10A Circuit breaker Module air intake I O Panel Knockout rear cover panel BUTTON FUNCTION MENU Access the set up and menu functions UP Scroll menu function...

Страница 5: ...orced air cooling and the following guidelines should be applied during installation 1 The rack enclosure must maintain a 4 inch minimum clearance on the entire left side of the dimmer rack The rack e...

Страница 6: ...codes to determine the proper wire type and wiring methods for your regional installation Input Power SINGLE PHASE THREE PHASE L L1 L2 L3 N N N N E E E 1 phase 3 wire 120 240 VAC 120 Amps 50 60Hz POW...

Страница 7: ...1 DGND 2 DATA 3 DATA ANALOG 0 10VDC Input 15 pin M D Sub Pin Signal 1 Channel 1 2 Channel 2 3 Channel 3 4 Channel 4 5 Channel 5 6 Channel 6 7 Channel 7 8 Channel 8 9 Channel 9 10 Channel 10 11 Channel...

Страница 8: ...led and shortly after will enter standby mode Menu Navigation First line displays dimming levels of each channel Second line displays the channel A C 10 12 1 2 3 4 5 6 7 8 9 A B C 1 2 3 4 5 6 7 8 9 A...

Страница 9: ...will behave if you were to loose the DMX controller s signal to the dimmer Action 1 Press the MENU button to enter the setup menu 2 Press the UP and DOWN buttons to scroll menu items until you reach...

Страница 10: ...button to enter the sub menu BLOCK 1 Press the ESC button to confirm 2 Press UP DOWN buttons to select the start address between 001 and 512 SINGLE 1 In Chan 1 Single Channel mode press MENU to change...

Страница 11: ...Chan 1 1 In Chan 1 Single Channel mode press MENU to change between the channel and its start address as noted by the cursor 2 In Chan press UP DOWN buttons to select channels 1 12 In 001 press UP DO...

Страница 12: ...buttons to select between All Single Channel mode ALL All 1 Press UP DOWN to select the master dimmer level value between 000 100 for all channels SINGLE CHANNEL Chan 1 1 In Chan 1 Single Channel mod...

Страница 13: ...one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order...

Страница 14: ...without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sur...

Страница 15: ...ut 4 wire GD 120 230 VAC 120 Amps 50 60Hz OUTPUT CAPACITY 120VAC 12 channels 1200 Watts per channel 120VAC 230VAC 12 channels 2300 Watts per channel 230VAC OUTPUT PANEL Hard wired terminal blocks OVER...