Safety Instructions 

 

 

Please read these instructions carefully, which includes important 
information about the installation, usage and maintenance of this 
product. 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that 
they also receive this instruction booklet. 

 

Always make sure that you are connecting to the proper voltage, and that the line voltage you are 
connecting to is not higher than that stated on the decal or rear panel of the fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no 
flammable materials close to the unit while operating. 

 

The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent 
surfaces. Be sure that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or replacing the fuse and be sure to replace 
with same fuse type and rating. 

 

Secure unit to fastening device using a safety chain. 

 

Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate unit at temperatures higher than 
this.  

 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair the 
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 
contact the nearest authorized technical assistance center. Always use the same type spare parts. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure the power cord is never crimped or damaged. 

 

Never disconnect the power cord by pulling or tugging on the cord. 

 

Avoid aiming the unit at people while it is on.  

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET at: 954-929-1115. 

 

 
 
 
 

SM-80 User Manual 

2006-12-13/15:33

 

Содержание SM-80

Страница 1: ...ctivated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle SM 80 Mini Snow Machine USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Страница 2: ...ION 5 FEATURES 5 PRODUCT OVERVIEW 5 3 SETUP 6 SNOW FLUID 6 FUSE REPLACEMENT 6 MOUNTING 6 Orientation 6 Rigging 6 4 OPERATING INSTRUCTIONS 7 MANUAL OPERATION 7 TIMER OPERATION 7 TROUBLESHOOTING 8 TECHNICAL SUPPORT 8 5 APPENDIX 8 GENERAL MAINTENANCE 8 RETURNS PROCEDURE 9 CLAIMS 9 TECHNICAL SPECIFICATIONS 9 SM 80 User Manual 2 2006 12 13 15 33 ...

Страница 3: ...listed current rating is its average current draw under normal conditions All units must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a unit check that the source voltage matches the unit s requirement Warning Verify that the voltag...

Страница 4: ...blocked Always disconnect from power source before servicing or replacing the fuse and be sure to replace with same fuse type and rating Secure unit to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate unit at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by your...

Страница 5: ...rm up time Disperses snow over a large area Wired timer remote included Product Overview Manual Snow Button Handle Fluid Tank Nozzle At the rear Fuse holder Remote control socket Air volume knob Safety Hook Timer Remote SM 80 User Manual 5 2006 12 13 15 33 ...

Страница 6: ...tting on a level surface or it may be mounted using the bracket provided Ensure that the snow is not shooting directly at anyone s face Whatever method of installation you choose the snow machine must not have more than a 15 degree angle of inclination tilt RIGGING Hanging Clamp It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust t...

Страница 7: ...remote control unit into the socket at the rear of the unit 2 On the rear of the unit choose desired air volume by adjusting the air volume knob 3 Press the power switch on the remote Red indicator light will illuminate to indicate unit is working 4 Press the TIMER button on the remote control to activate the timer 5 Use the INTERVAL knob to adjust the time period between outputting snow Clockwise...

Страница 8: ...33020 U S A Support Email tech chauvetlighting com Telephone 954 929 1115 Press 4 Fax 954 929 5560 Attention Service Website http www chauvetlighting com 5 APPENDIX General Maintenance Warning If your snow machine will be stored for more than 30 days it must be purged before being stored Failure to do so will void your warranty To purge your fogger or snow machine follow the instructions below You...

Страница 9: ...3 Your phone number 4 The RA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing co...

Отзывы: